Eagle Mountain, UT Noise Ordinances: Decibel Limits (2026)
Key Facts
- Most-zone cap
- 65 dBA during restricted hours
- Industrial/Light Mfg cap
- 75 dBA during restricted hours
- Absolute ceiling
- 85 dBA violation at any time
- Measurement distance
- 25 feet from source or property line
- Governing section
- EMMC 8.15.070(B), Table 8.15.070(1)
Summary
Eagle Mountain caps most zones at 65 dBA during restricted hours under EMMC 8.15.070(B) and its zoning table, with industrial and light manufacturing zones allowed up to 75 dBA. Any sound of 85 decibels or louder is a violation at any time, in any zone.
B. Per Se Noise Disturbances. Notwithstanding anything to the contrary in this chapter, it shall be unlawful and constitute a per se noise disturbance to make and/or create a sound that exceeds the maximum allowable decibel level as outlined in this subsection. ... 2. Maximum Permissible Sound Level. A per se noise disturbance during restricted hours occurs when the sound level exceeds the maximum permissible sound level listed for the zoning classification, as established in Table 8.15.070(1). A measurement of 85 decibels or above shall be considered to be a noise disturbance at any time. ... Table 8.15.070(1) Hours of Restriction – Maximum Permissible Sound Levels (dBA) Zone1 Abbr dBA Zone Abbr dBA ... Multifamily 1 MF1 65 Industrial I 75 ... Any other zone not listed shall have a maximum permissible sound level of 65 dBA during the hours of restriction.
Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance O-34-2026, passed August 4, 2026).
Full Breakdown
070(B) creates a "per se" noise disturbance standard that doesn't depend on proving a sound is annoying, only on measuring it. 070(1) sets the maximum permissible sound level, in A-weighted decibels, for every zoning classification during restricted hours: 65 dBA covers every residential zone (R1, R2, R3, Residential Cottage), every rural and agricultural zone (RA1, RA2, RD1, RD2), the commercial zones (Commercial Neighborhood, Community and Regional), Foothill Residential, Multifamily 1 and 2, Public Facilities, and both open space classifications. Only the Industrial (I) and Light Manufacturing/Distribution (LMD) zones get a higher ceiling, 75 dBA.
Any zone the table doesn't list defaults to the same 65 dBA cap, and the planning director can set an equivalent limit for historical zones that predate the table. 070(B)(1), a suspected per se violation is measured at least 25 feet from the source, whether that's from the public right-of-way or from the property line on private land, using a decibel meter on the "A" weighing scale. 070(B)(2) sets one absolute ceiling: 85 decibels or above is automatically a noise disturbance at any time of day, in any zone, with no zone-specific exception.
The table also protects properties near a zone boundary: if a sound is plainly audible in a neighboring zone with a stricter limit, the stricter zone's cap controls, not the source zone's.
Violations & Fines
Exceeding the zone's dBA cap under Table 8.15.070(1), or hitting 85 decibels or louder at any time, is a per se noise disturbance under EMMC 8.15.070(B). Eagle Mountain treats a Chapter 8.15 violation as a Class B misdemeanor under EMMC 8.15.040, punishable by up to a $1,000 fine and up to six months of incarceration, or both, with each day of continued violation counting separately.
Frequently Asked Questions
What's the noise limit in a residential zone in Eagle Mountain?
Are industrial zones allowed louder noise in Eagle Mountain?
Is there a noise level that's always a violation in Eagle Mountain, no matter the zone?
Sources & Official References
Other rules in Eagle Mountain
Compare Eagle Mountain to another location·View the Utah noise ordinances overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Decibel Limits in Nearby Cities
How other cities in Utah County handle decibel limits.