Skip to main content
CityRuleLookup

Plantation, FL Outdoor Lighting: Dark Sky Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified July 2026

Key Facts

Pole height, non-cut-off
25 feet above grade
Pole height, cut-off
30 feet above grade
Spillover limit
0.5 footcandles at property line
Vehicular use area maximum
15 footcandles
Lighting plan
Registered professional engineer required

Summary

Sec. 27-293 requires an engineer-prepared photometric plan, caps light spillover at 0.5 footcandles at the property line, limits vehicular use areas to 15 footcandles, and holds mounting heights to 25 or 30 feet.

All private outdoor lighting shall be designed, located and mounted at heights no greater than: (1) 25 feet above grade for non-cut-off type luminaries, and (2) 30 feet above grade for cut-off type luminaries.

Source: City of Plantation Code of Ordinances (Municode)View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 30 Update 1).

Full Breakdown

Section 27-293 of the Land Development Regulations governs all outdoor lighting. Light must be aimed at the ground, a vehicular use area, a building entrance, walkway or sign; lighting designed to illuminate a building elevation or roof area is prohibited. A photometric site lighting plan must be prepared by a registered professional engineer and submitted with the site plan. Multi-family, shopping centers and office buildings must light parking and pedestrian areas to a minimum maintained average of 1.0 footcandle, with no area below 0.5. Spillover may not exceed 0.5 footcandles at the property line, and no point in a vehicular use area may exceed 15. Poles are capped at 25 feet for non-cut-off luminaires, 30 feet for cut-off.

Violations & Fines

Sec. 27-293(a) says no structure or land may be developed, used or occupied unless its outdoor lighting conforms, so non-compliant fixtures have to be reaimed, shielded, lowered or replaced before approval.

Frequently Asked Questions

Does Plantation have outdoor lighting rules?
Yes. Sec. 27-293 sets minimum and maximum illumination, caps spillover at 0.5 footcandles measured vertically along the property line, and limits mounting height to 25 feet non-cut-off or 30 feet cut-off.
Are there dark-sky or sea-turtle lighting rules in Plantation?
Sec. 27-293 is a glare, spillover and mounting-height standard rather than a dark-sky or sea-turtle ordinance. Public parks and lighted athletic fields are exempt from it entirely.

Sources & Official References

Other rules in Plantation

All Plantation rules

Florida rules heatmap·Compare Plantation to another location·View the Florida outdoor lighting overview

Get notified when Dark Sky Rules in Plantation, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Dark Sky Rules in Nearby Cities

How other cities in Broward County handle dark sky rules.

Pembroke Pines, FL
Some Restrictions
Miramar, FL
Some Restrictions
Pompano Beach, FL
Some Restrictions
Hollywood, FL
Significant Restrictions
Fort Lauderdale, FL
Significant Restrictions