Waco, TX Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Applies to
- Brazos River Corridor (BRC) overlay district only
- Shielding standard
- No direct light above 90° fixture cutoff angle
- Wiring
- All wiring must be installed underground
- Poles
- Wood utility poles prohibited; wood specialty fixtures may qualify
- Adopted
- Ord. No. 2023-431, effective June 6, 2023
- Enforcement trigger
- New construction or substantial renovation review
Summary
Within Waco's Brazos River Corridor overlay district, Section 28-809.1(e) requires that all outdoor lighting be shielded or constructed so no direct light escapes upward past the fixture's 90-degree cutoff angle, either from the lamp itself or from the fixture housing, a full-cutoff standard aimed at protecting the corridor's night sky and neighboring properties from glare.
Lighting shall be shielded or constructed so that no direct light is emitted upward, either directly from the lamp or indirectly from the fixture, above the 90° cutoff angle of the fixture.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 88).
Full Breakdown
The Brazos River Corridor (BRC) district is a zoning overlay that layers additional development standards, including outdoor lighting rules, on top of whatever base R, O, C, or M district a property carries under Section 28-798; a lot in the BRC has to satisfy both its base-district zoning and the corridor's design standards. Section 28-809, the division's purpose statement, explains that lighting in the corridor is meant to provide a safe, secure atmosphere while remaining "unobtrusive to surrounding property," and lighting may be required for parking areas, walks and drives that stay in use after dark.
1 then sets the mechanics: supports and fixtures must be compatible with the area's character, wood utility poles are barred (though specially designed wood fixtures may be considered), and all wiring must run underground. Subsection (e) is the shielding rule: fixtures must be shielded or built so that no direct light is emitted upward, either straight from the lamp or indirectly off the fixture, above the fixture's 90-degree cutoff angle. That full-cutoff design keeps light off the sky and out of the corridor's tree canopy and waterway, and it applies on top of the base zoning code, which does not otherwise regulate light direction outside this overlay.
The rule was readopted as part of the 2023 overhaul of Division 23 (Ord. No. 2023-431, June 6, 2023), which replaced the corridor's earlier lighting language in its entirety.
Violations & Fines
A fixture that throws light above the 90-degree cutoff in the BRC overlay is out of compliance with Section 28-809.1(e), and the city's development review process, triggered by any new construction or substantial renovation in the corridor under Section 28-799, can require the fixture be replaced or retrofitted with shielding before a certificate of occupancy issues. Single-family homes in R-E, R-1A, or R-1B zones within the corridor are exempt from most BRC design sections, but Section 28-809.1's lighting shielding rule is not among the sections listed as excepted.
Frequently Asked Questions
Does Waco's dark-sky lighting rule apply citywide?
What lighting standard must BRC properties meet?
Are single-family homes in the corridor exempt from the lighting rule?