Lower Merion, PA Outdoor Lighting: Light Trespass & Shielding (2026)
Key Facts
- Trespass limit near LDR 1-3 conforming lots
- 0.1 fc
- Trespass limit, nonresidential abutting residential
- 0.1 fc
- Trespass limit near LDR 4/MDR 1-3
- 0.2 fc
- Trespass limit near compatible nonresidential use
- 0.3 fc
- Mounting height ceiling
- 12 feet absent trespass/glare showing
Summary
Lower Merion Township caps light spilling onto neighboring land at 0.1 to 0.3 footcandle at the property line depending on the adjoining use, and limits most luminaire mounting heights to 12 feet, under Township Code Section 105-12.
Luminaires shall not be mounted in excess of 12 feet above finished grade of the surface being illuminated, unless it can be demonstrated that taller lighting would not increase light trespass or glare onto adjacent properties. ... Light trespass shall be controlled as follows: Table 13.3 Light Trespass Location Maximum Vertical Illuminance at any point in the perimeter plane of the property Lots with conforming structures in the LDR 1-3 Districts 0.1 fc Where any non-residential use abuts any residential use or District 0.1 fc Adjacent to medium/high density residential use or District including but not limited to LDR 4 and MDR 1-3, or non-conforming structures in LDR 1-3 Districts 0.2 fc Adjacent to compatible non-residential use or District 0.3 fc
Full Breakdown
Section 105-12.C(1) of the Lower Merion Township Code sets numeric light-trespass limits in Table 13.3, measured as maximum vertical illuminance at any point in the perimeter plane of the property. Lots with conforming structures in the LDR 1-3 Districts, and any spot where a non-residential use abuts a residential use or district, are held to 0.1 footcandle. Locations adjacent to medium- or high-density residential districts, including LDR 4 and MDR 1-3, or adjacent to non-conforming structures in the LDR 1-3 Districts, are allowed 0.2 footcandle.
Sites adjacent to a compatible non-residential use or district get the loosest limit, 0.3 footcandle. Section 105-12.B(2) backs the trespass table with a mounting-height ceiling: luminaires cannot be mounted higher than 12 feet above finished grade of the surface being illuminated, unless the applicant demonstrates that a taller fixture would not increase light trespass or glare onto adjacent properties. Section 105-12.C(2) adds a companion Allowable Luminaire Glare Rating table (13.4) that limits fixture glare by zone depending on the abutting use. The Township's LIGHT TRESPASS definition in Section 105-11, light that falls beyond the property it is intended to illuminate, frames why these numbers exist: they stop a commercial or larger residential lot's lighting plan from washing out a neighbor's yard or windows.
Compliance is checked at permit stage under Section 105-12.C, which for Major Lighting Submissions requires a Point Method illumination plan extending 10 feet beyond the property lines.
Violations & Fines
A lighting installation that exceeds the Table 13.3 vertical illuminance limits at the property line, or a luminaire mounted above 12 feet without a showing that it will not increase trespass or glare, is out of compliance with Section 105-12 and can be held at permit review or ordered corrected by the Building and Planning Department; Chapter 105's general penalty framework in Section 105-7, fines of $100 to $1,000 per offense with each day a separate offense, applies.
Frequently Asked Questions
How much light can spill onto my property from a neighbor's commercial lot in Lower Merion?
How tall can a parking lot light pole be in Lower Merion Township?
Does the Township limit light trespass the same way for all neighboring zones?
Sources & Official References
Other rules in Lower Merion
Compare Lower Merion to another location·View the Pennsylvania outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Light Trespass & Shielding in Nearby Cities
How other cities in Montgomery County handle light trespass & shielding.