Skip to main content
CityRuleLookup

Prescott Valley, AZ Parking Rules: Loading Zones (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Applies in
All zoning districts except AG (agricultural)
Up to 30,000 square feet
1 loading space
30,001 to 50,000 square feet
2 loading spaces
50,001 to 150,000 square feet
3 loading spaces
Space size
12 feet wide, 45 feet long, 14 feet high
Prohibited locations
Any front yard; never counted as parking space

Summary

In the Town of Prescott Valley, Arizona, every premises outside the AG zone with a building occupied by a use that receives or distributes materials or goods must provide off-street loading space: one space up to 30,000 square feet of floor area, then two, then three, with an additional space for each further block. Each space measures 12 by 45 feet with 14 feet of height, and none is permitted in a front yard.

A. Applicability: ... In all zoning districts except AG (agricultural), off- street loading space meeting the minimum requirements specified in this section shall be provided and maintained on each premises with one or more buildings occupied by a use that receives or distributes materials or goods. B. Schedule of loading space requirements: Total floor area of building Required number of loading spaces Up to 30,000 square feet 1 30,001 to 50,000 square feet 2 50,001 to 150,000 square feet 3 Each additional one to 100,000 square feet 1 additional C. Location: 1. Required off-street loading space shall not be permitted: a. In any front yard. ... 3. Loading space shall not be counted or included as off-street parking space. ... E. Size: ... Each off-street loading space shall meet the following minimum requirements: 1. Width: 12 feet 2. Length: 45 feet 3. Height: ... 14 feet exclusive of access aisles and maneuvering space

Full Breakdown

Section 13-10-060 of the Prescott Valley Town Code requires off-street loading space in all zoning districts except AG (agricultural), on each premises with one or more buildings occupied by a use that receives or distributes materials or goods. The schedule is by total floor area of the building: one space up to 30,000 square feet, two spaces from 30,001 to 50,000 square feet, three spaces from 50,001 to 150,000 square feet, and one additional space for each additional one to 100,000 square feet.

Subsection C controls location. Required loading space is not permitted in any front yard, and not in a required side yard except in a non-residential zoning district where a side yard abuts an alley within and that abuts only non-residential zoning districts. Loading space can occupy all or part of a required rear yard and can be partially or entirely enclosed within a building, but it is never counted as off-street parking space. Under subsection D, an alley within and abutting only non-residential zoning districts can serve as maneuvering space. Subsection E sets the minimum size of each space at 12 feet wide, 45 feet long, and 14 feet high, exclusive of access aisles and maneuvering space.

The site development article adds screening. Section 13-11-050(D)(3) requires loading, delivery, or service areas to be oriented away from public streets or screened by six-foot high screen walls with adjacent screening landscaping, and screened from contiguous residential zoning districts by six-foot high screen walls and screening trees. Overhead bay doors must face away from major streets, highways, and contiguous residential districts or be screened the same way. Section 13-10-060 was rewritten by Ordinance No. 2024-947 on December 11, 2024, and previously stood at section 13-24-060; the loading rule was first enacted by Ordinance No. 152 on July 2, 1987.

Violations & Fines

A violation of the loading requirements is a violation of Chapter 13. Section 13-15-020 makes it unlawful to use land in violation of the Chapter and treats each individual day a violation continues as a separate offense. Under section 13-15-030, a person found guilty is guilty of a Class 3 misdemeanor unless the Chapter specifies otherwise, and section 13-15-040 lets the Council, the Town Attorney, the Zoning Administrator, or a property owner with legal standing seek injunction, mandamus, or abatement.

Frequently Asked Questions

How many loading spaces does a Prescott Valley building need?
The count follows total floor area under section 13-10-060(B): one space up to 30,000 square feet, two from 30,001 to 50,000 square feet, three from 50,001 to 150,000 square feet, and one additional space for each additional one to 100,000 square feet. The requirement applies to uses that receive or distribute materials or goods.
Can a loading space be in the front yard?
No. Subsection C.1.a prohibits required off-street loading space in any front yard. A required side yard is also off limits except in a non-residential zoning district where the side yard abuts an alley within and abutting only non-residential districts. A required rear yard can hold loading space.
How big must a loading space be?
Subsection E sets the minimum at 12 feet wide, 45 feet long, and 14 feet high, exclusive of access aisles and maneuvering space. An alley within and abutting only non-residential zoning districts can serve as maneuvering space for loading spaces under subsection D.
Can a loading space count toward required parking?
No. Subsection C.3 states that loading space shall not be counted or included as off-street parking space. A business needs the parking spaces its use requires under Article 13-10 and, separately, the loading spaces the floor-area schedule requires.

Sources & Official References

Other rules in Prescott Valley

All Prescott Valley rules

Compare Prescott Valley to another location·View the Arizona parking rules overview

Get notified when Loading Zones in Prescott Valley, AZ changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Loading Zones in Nearby Cities

How other cities in Yavapai County handle loading zones.

Sedona, AZ
Light Restrictions