Burleson, TX Building Safety: Door Locking Hardware (2026)
Key Facts
- Code adopted
- 2021 International Building Code, § 10-141
- Amended section
- Section 1010.2.5 Bolt Locks, exceptions 3 and 4
- Exception 3 threshold
- Occupant load of less than 50 persons, Group B, F, M or S
- Exception 4 occupancies
- Pair of doors serving Group A, B, F, M or S
- Fire pump room access door
- Not less than 3 ft. wide and 6 ft. - 8 in. high
- Dangerous-building fine
- Not more than $2,000.00 per offense, § 10-453(e)
Summary
In the City of Burleson, Texas, § 10-142 amends Section 1010.2.5 (Bolt Locks) of the 2021 International Building Code by rewriting exceptions 3 and 4. Exception 3 covers a pair of doors serving an occupant load of less than 50 persons in a Group B, F, M or S occupancy. Exception 4 covers a pair of doors serving a Group A, B, F, M or S occupancy.
Section 1010.2.5 Bolt Locks; amend exceptions 3 and 4 as follows: Exceptions: 3. Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F, M or S occupancy. {Remainder unchanged} 4. Where a pair of doors serves a Group A, B, F, M or S occupancy {Remainder unchanged}
Full Breakdown
The Burleson City Council adopts the 2021 International Building Code in § 10-141 and amends it in § 10-142, last revised by Ord. No. 5247-10-2023 on 10-2-2023. Amendment (67) is the only door-hardware change in that list. It reaches Section 1010.2.5 Bolt Locks and replaces exceptions 3 and 4. Exception 3 applies where a pair of doors serves an occupant load of less than 50 persons in a Group B, F, M or S occupancy. Exception 4 applies where a pair of doors serves a Group A, B, F, M or S occupancy. Each carries the note {Remainder unchanged}, so the rest of each exception stays as written in the base code, which the ordinance incorporates by reference and does not reprint.
Other door and exit amendments sit nearby. Section 913.2.1.1 requires a ground-level fire pump room on an exterior wall to have an exterior fire department access door not less than 3 ft. in width and 6 ft. - 8 in. in height, with a key box at that door as required by Section 506.1. For houses, § 10-172 amends Section R302.5.1 so openings from a private garage directly into a room used for sleeping purposes are not permitted, and other garage openings need solid wood doors not less than 13/8 inches (35 mm) thick, solid or honeycomb core steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors equipped with a self closing device.
Existing buildings face a separate test. Under § 10-455(3), an owner of a commercial building shall not obstruct passage through stairwells, corridors, or doors and shall place the street address number on the rear door in letters at least four inches high. Under § 10-454(a)(1), a door, aisle, passageway, stairway or other means of exit that is not of sufficient width or size, or not arranged to give a safe and adequate means of exit in case of fire or panic, makes a building dangerous when the life, health, property or safety of the public or occupants is endangered. The building official or the official's designee enforces the codes adopted in the chapter under § 10-53.
Violations & Fines
Violations of the building code amendments fall under § 1-14: a fine not exceeding $500.00 where no specific penalty is provided and a fine not exceeding $2,000.00 for provisions governing fire safety, zoning, or public health and sanitation, with each day a separate offense. Dangerous-building violations under § 10-453(e) carry a fine of not more than $2,000.00 for each separate offense, and each day or portion of a day is its own offense.
Frequently Asked Questions
Does the City of Burleson change the bolt lock rule in the building code?
Who enforces door hardware rules in the City of Burleson?
Do doors between a Burleson garage and the house need to be fire rated?
Sources & Official References
Other rules in Burleson
Texas rules heatmap·Compare Burleson to another location·View the Texas building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.