Key Facts

Energy code adopted
2021 International Energy Conservation Code, § 10-351
Alternative compliance
Energy Star certification of energy code equivalency counts
1- and 2-family dwellings
Tested for air and duct leakage
Outlet box air leakage
Not greater than 2.0 cubic feet per minute at 75 Pa
Multifamily sampling
Greater of seven units or 20 percent of testing units
Deleted provisions
Sections R401.2.5 and R404.2

Summary

The City of Burleson, Texas adopts the 2021 edition of the International Energy Conservation Code as the energy conservation code of the city in § 10-351, with local amendments in § 10-352. Each 1- and 2-family dwelling is tested for air and duct leakage, and Energy Star certification of energy code equivalency counts as compliance.

The 2021 edition of the International Energy Conservation Code of the International Code Council, as hereinafter amended, is from the effective date hereof herby adopted as the energy conservation code of the city. One copy of such International Energy Conservation Code is incorporated herein by reference and shall have been filed for permanent record and inspection in the office of the city secretary.

Full Breakdown

Section 10-351 adopts the 2021 International Energy Conservation Code as the energy conservation code of the city and incorporates one copy by reference, filed for permanent record and inspection in the office of the city secretary. Section 10-352 then amends it. Amendment (1) adds Sections C102.1.2 and R102.1.2, Alternative Compliance: a building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance can, at the option of the Code Official, be considered in compliance, and the United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Regardless of the path to compliance, each 1- and 2-family dwelling shall be tested for air and duct leakage under Sections R402.4.1.2 and R403.3.3.

Other changes follow. Section R401.2.5 Additional Energy efficiency and Section R404.2 Interior Lighting Controls are deleted in their entirety. Section R402.4.6 requires electrical and communication outlet boxes in the building thermal envelope to be sealed, tested to NEMA OS 4, with an air leakage rate of not greater than 2.0 cubic feet per minute (0.944 L/s) at a pressure differential of 1.57 psf (75 Pa), and marked "NEMA OS 4" or "OS 4". For R2 multifamily buildings with eight or more testing units, Sections R402.4.1.4, R403.3.8 and R403.6.4 allow sampling: the greater of seven units or 20 percent of the testing units, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit area. Each tested unit that fails adds three more units, and buildings with fewer than eight testing units test every unit. In the residential code, § 10-172 deletes Chapter 11 [RE] Energy Efficiency in its entirety and replaces it.

The building official enforces the adopted codes (§ 10-53), and the Building Codes and Standards Board hears appeals on the International Energy Conservation Code under § 10-79.

Violations & Fines

Violations are punished under § 1-14: a fine not exceeding $500.00 where no specific penalty is provided, with a maximum fine not exceeding $2,000.00 for provisions governing fire safety, zoning, or public health and sanitation. Each day a violation continues is a separate offense under § 1-14(c). The Building Codes and Standards Board has no authority to waive any requirement of the energy code (§ 10-79(b)).

Frequently Asked Questions

Which energy code does the City of Burleson use?
The 2021 edition of the International Energy Conservation Code, adopted in § 10-351 as the energy conservation code of the city, with one copy incorporated by reference and filed in the office of the city secretary. Section 10-352 lists the Burleson amendments, including alternative compliance, deleted provisions and multifamily sampling rules.
Does an Energy Star certification satisfy the energy code in Burleson?
Section R102.1.2 as added by § 10-352 says the United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Even so, each 1- and 2-family dwelling shall be tested for air and duct leakage as prescribed in Sections R402.4.1.2 and R403.3.3, regardless of the program or path to compliance.
How are multifamily buildings tested for air leakage in the City of Burleson?
For R2 buildings with eight or more testing units, the greater of seven units or 20 percent of the testing units is tested, including a top floor unit, a ground floor unit, a middle floor unit and the unit with the largest testing unit enclosure area. For each tested unit over the maximum air leakage rate, three additional units are tested. Buildings with fewer than eight testing units test each one.

Sources & Official References

Other rules in Burleson

All Burleson rules

Texas rules heatmap·Compare Burleson to another location·View the Texas building safety overview

Get notified when Green Building Code in Burleson, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.