Burleson, TX Building Safety: Elevator Maintenance (2026)
Key Facts
- Amended elevator sections
- IBC Sections 3002.1 through 3008.3, § 10-142
- Machine room storage
- Not allowed; approved signage at each entry
- Sprinklers in machine rooms and hoistways
- Prohibited, Section 3005.5.1.1.1
- Shunt trip
- Omitted, Section 3005.5.1.3
- Sprinkler chapter signage text
- ELEVATOR MACHINERY - NO STORAGE ALLOWED
- Maximum fine, fire safety provisions
- $2,000.00 under § 1-14(b)
Summary
In the City of Burleson, Texas, § 10-142 amends the elevator chapter of the 2021 International Building Code. Storage is not allowed in an elevator machine room, control room, machinery space or control space, and each entry needs approved signage stating "No Storage Allowed." Sprinklers are prohibited in machine rooms and hoistways, and the shunt trip is omitted.
Section 3002.1 Hoistway Enclosure Protection; add exceptions to read as follows: Exceptions: 1. Elevators wholely located within atriums shall not require hoistway enclosure protection. 2. Elevators in open or enclosed parking garages that serve only the parking garage, and complying with Sections 406.5 and 406.6, respectively, shall not require hoistway enclosure protection. ... 3005.5.1.1.1 Prohibited locations. Automatic sprinklers shall not be installed in machine rooms, elevator machinery spaces, control rooms, control spaces and elevator hoistways. ... 3005. ... 5.1.3 Omission of Shunt trip. Means for elevator shutdown in accordance with Section 3005.5 shall not be installed. ... 3005.8 Storage. Storage shall not be allowed within the elevator machine room, control room, machinery spaces and or control spaces. Provide approved signage at each entry to the above listed locations stating: "No Storage Allowed."
Full Breakdown
The City Council adopts the 2021 International Building Code in § 10-141 and amends the elevator provisions in § 10-142, amendments (78) through (83). Hoistway enclosure: Section 3002.1 gets two exceptions. Elevators wholly located within atriums need no hoistway enclosure protection, and neither do elevators in open or enclosed parking garages that serve only the parking garage and comply with Sections 406.5 and 406.6, respectively. Section 3005.4 deletes the earlier exceptions and adds two parallel ones: machine rooms, control rooms, machinery spaces and control spaces need no enclosure protection when completely located within atriums or when located in parking garages that serve only the garage.
Machine room fire protection: Section 3005.5.1.1 requires the building to be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, yet Section 3005.5.1.1.1 prohibits sprinklers in machine rooms, elevator machinery spaces, control rooms, control spaces and elevator hoistways. The sprinkler system carries a control valve supervisory switch and a water-flow initiating device for each floor, monitored by the building's fire alarm system. Section 3005.5.1.2 requires an approved method to keep water from sprinkler operation outside the elevator lobby out of the hoistway enclosure, and Section 3005.5.1.3 omits the shunt trip.
Storage: Section 3005.8 bans storage in the machine room, control room, machinery spaces and control spaces. The amended Section 903.2 repeats the ban for the elevator machine room and calls for signage at the entry doors indicating "ELEVATOR MACHINERY - NO STORAGE ALLOWED." Sections 3007.3 and 3008.3 are revised by deleting "enclosed" from their water protection text.
The building official or the official's designee enforces these amendments under § 10-53.
Violations & Fines
Section 1-14(a) sets a fine not exceeding $500.00 where no specific penalty is provided, while § 1-14(b) sets a maximum fine not exceeding $2,000.00 for provisions governing fire safety, zoning, or public health and sanitation. Each day a violation continues is a separate offense under § 1-14(c). Technical determinations by the building official can be appealed to the Building Codes and Standards Board under § 10-79, and that board has no authority to waive code requirements.
Frequently Asked Questions
Can a building owner store items in an elevator machine room in the City of Burleson?
Does Burleson require sprinklers inside elevator machine rooms?
Do elevators in a parking garage need a hoistway enclosure in the City of Burleson?
Sources & Official References
Other rules in Burleson
Texas rules heatmap·Compare Burleson to another location·View the Texas building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.