Key Facts

Energy code inspection stages
Footing and foundation, framing, insulation, plumbing, mechanical, final
Final inspection
Building shall not be occupied until approved
Re-inspection fee
Set by city council resolution, Section 109.7 in § 10-142
Red-tag trigger
Job site red-tagged twice for the same item
Enforcement
Building official or designee, § 10-53
Energy code adopted
2021 International Energy Conservation Code, § 10-351

Summary

In the City of Burleson, Texas, § 10-352 sets the required inspections under the 2021 Energy Conservation Code: footing and foundation, framing and air barrier rough-in, insulation and fenestration rough-in, plumbing rough-in, mechanical rough-in and a final inspection. A building shall not be occupied until the final inspection approves it.

Section 105.2 Required Inspections; Changed numbering and to read as follows: R105.2.1 Footing and foundation inspection. Inspections associated with footings and foundations shall verify compliance with the code as to R-value, location, thickness, depth of burial and protection of insulation as required by the code and approved plans and specifications. R105.2.2 Framing and Air Barrier rough-in inspection. Inspections at framing and rough-in shall be made before application of interior finish insulation and shall verify compliance with the code as to: types of insulation and corresponding R values and their correct location and proper instillation; fenestration properties such as U factor and SHGC and proper instillation; air leakage controls as required by the code; and approved plans and specifications. ... R105.2. ... 56 Final inspection. The building shall have a final inspection and shall not be occupied until approved. The final inspection shall include verification of the installation of all required building systems, equipment and controls and their proper operation and the required number of high-efficacy lamps and fixtures.

Full Breakdown

Amendment (2) to the 2021 International Energy Conservation Code in § 10-352 renumbers and rewrites Section 105.2 Required Inspections. The stages run in this order. R105.2.1 is the footing and foundation inspection, verifying R-value, location, thickness, depth of burial and protection of insulation. R105.2.2 is the framing and air barrier rough-in, made before application of interior finish insulation, checking types of insulation and R values, fenestration properties such as U factor and SHGC, and air leakage controls. R105.2.3 is the insulation and fenestration rough-in, made before application of interior finish. R105.2.34 is the plumbing rough-in, checking insulation, R-values, protection and required controls. R105.2.45 is the mechanical rough-in, covering HVAC equipment type and size, controls, system insulation, system air leakage control, programmable thermostats, dampers, whole-house ventilation and minimum fan efficiency. R105.2.56 is the final inspection, which verifies installation of all required building systems, equipment and controls and their proper operation and the required number of high-efficacy lamps and fixtures. Systems serving multiple dwelling units are inspected under Section C105.2.4.

The wider inspection process sits in other sections. The building official or designee is authorized and directed to enforce the codes adopted in Chapter 10 (§ 10-53). Section 109.7 in § 10-142 allows a re-inspection fee set by city council resolution when the inspection is not ready when the inspector arrives, no building address or permit card is clearly posted, city approved plans are not on the job site, the building is locked or work is not available, the job site is red-tagged twice for the same item, the original red tag is removed, or erosion control, trash control or tree protection is not maintained. Any such fee shall be paid before any more inspections are made on that job site. Section R108.7 in § 10-172 sets a similar fee for houses. Sections R110.1 through R110.5 are deleted from the residential code, and the exception to Section 110.3.5 on lath, gypsum board and gypsum panel product inspection is deleted from the building code.

Under § 10-453(f), all construction or work for which a permit is required is subject to inspection by the director of code enforcement or members of the inspection team.

Violations & Fines

A job that is not ready when the inspector arrives, or that is red-tagged twice for the same item, draws a re-inspection fee set by city council resolution, payable before any further inspection. Code violations are punished under § 1-14 with a fine not exceeding $500.00 where no specific penalty is provided and not exceeding $2,000.00 for fire safety, zoning, or public health and sanitation provisions, each day a separate offense.

Frequently Asked Questions

What inspections does the City of Burleson require under the energy code?
Section 105.2 as rewritten in § 10-352 lists a footing and foundation inspection, a framing and air barrier rough-in, an insulation and fenestration rough-in, a plumbing rough-in, a mechanical rough-in and a final inspection. The framing and insulation inspections are made before application of interior finish, and systems serving multiple dwelling units follow Section C105.2.4.
Can a building be occupied before the final inspection in Burleson?
No. Section R105.2.56 says the building shall have a final inspection and shall not be occupied until approved. The final inspection verifies installation of all required building systems, equipment and controls and their proper operation, along with the required number of high-efficacy lamps and fixtures.
When does the City of Burleson charge a re-inspection fee?
Section 109.7 in § 10-142 lists the triggers: the inspection is not ready on arrival, no address or permit card is posted, approved plans are missing from the site, the building is locked, the site is red-tagged twice for the same item, the red tag is removed, or erosion control, trash control or tree protection fails. The fee is set by city council resolution and paid before more inspections.

Sources & Official References

Other rules in Burleson

All Burleson rules

Texas rules heatmap·Compare Burleson to another location·View the Texas building safety overview

Get notified when Building Inspections in Burleson, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.