Haverford, PA Building Safety: Fire Sprinkler Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Buildings covered by § 86-6
New institutional buildings, additions, conversions
Connection type
Five-inch Storz female couplings
Buildings facing two streets
Minimum of two connections
Connection height
Approximately two feet above ground
Enforcing office
Department of Codes Enforcement
Maximum fine
$1,000 plus costs

Summary

Haverford Township requires approved automatic sprinkler systems throughout newly erected institutional buildings, new additions to them, and existing buildings converted to institutional use. Connections must be five-inch Storz female couplings unless the Department of Codes Enforcement approves another cap type, and buildings facing two streets need at least two connections.

Approved automatic sprinkler systems shall be installed throughout all newly erected institutional buildings and new additions to institutional buildings and throughout existing buildings converted to institutional use after the effective date of this article. A. All sprinkler system connections, new and old, shall be five-inch Storz female couplings, caps and chains or other type caps approved by the Department of Codes Enforcement. B. The number and location of connections shall be as directed by the Department of Codes Enforcement; provided, however, that buildings that face on two streets shall have a minimum of two connections interconnected with the sprinkler system. The sprinkler system's connections shall be located approximately two feet above ground level or as otherwise directed by the Department of Codes Enforcement.

Full Breakdown

Section 86-6 of the Haverford Township Code is the Township's own sprinkler mandate. Approved automatic sprinkler systems must be installed throughout all newly erected institutional buildings, throughout new additions to institutional buildings, and throughout existing buildings converted to institutional use after the effective date of the article. The section was added 9-9-1974 by Ord. No. 1577 and amended in 1988 and 2012. This page covers what § 86-6 itself requires. Section 86-1 separately adopts the Uniform Construction Code as the municipal building code of Haverford Township, including the Fire Code, and that adopted code is a different instrument from this section.

The section also controls how the system hooks up for the fire service. Under subsection A, all sprinkler system connections, new and old, must be five-inch Storz female couplings, caps and chains, or another type of cap approved by the Department of Codes Enforcement. Under subsection B, the number and location of connections are set as directed by the Department, with one fixed floor: buildings that face on two streets need a minimum of two connections interconnected with the sprinkler system. The connections are located approximately two feet above ground level unless the Department directs otherwise.

Sprinklers also change what else a building must carry. Section 86-5(B)(1) requires commercial buildings to have a listed and labeled smoke or heat detection system with interconnected detectors sounding an alarm of at least 85 dBA throughout the premises, including an outside alarm, but states that this subsection does not apply to structures protected by a sprinkler system approved by the Fire Code Official. Section 86-5(G) separately fines a contractor $200 for a first false alarm, $400 for a second and $600 for each later one when a fire alarm system is not disabled before work. The Fire Prevention Code is enforced by the Department of Codes Enforcement under § 86-2, and appeals of a code official's decision go to the Board of Appeals of Delaware County under § 86-8.

Violations & Fines

Section 86-10 makes any violation of the Fire Prevention Code a summary offense before a Magisterial District Justice, with a fine not exceeding $1,000 and costs of prosecution and, in default of payment, up to 30 days in the county jail. After official notice, each day the violation continues is a separate offense punishable by a like fine. Under § 86-11 the Township or the Fire Marshal can also seek a court order to restrain or abate the violation.

Frequently Asked Questions

Which buildings in Haverford Township must have sprinklers under § 86-6?
Newly erected institutional buildings, new additions to institutional buildings, and existing buildings converted to institutional use after the article took effect. The system must be installed throughout the building. This section is the Township's own sprinkler mandate; the Uniform Construction Code adopted in § 86-1 is a separate instrument.
What kind of fire department connection is required?
All sprinkler system connections, new and old, must be five-inch Storz female couplings, caps and chains, or another cap type approved by the Department of Codes Enforcement. Buildings that face two streets need at least two connections interconnected with the sprinkler system.
Does a sprinkler system change the alarm requirements?
For commercial buildings, yes. Section 86-5(B)(1) exempts structures protected by a sprinkler system approved by the Fire Code Official from the whole-premises smoke and heat detection rule that otherwise requires an alarm of at least 85 dBA.
Who inspects and enforces sprinkler rules?
The Department of Codes Enforcement enforces the Fire Prevention Code under § 86-2 and directs connection number and location under § 86-6(B). Violations are prosecuted under § 86-10 with fines up to $1,000 plus costs, and appeals go to the Board of Appeals of Delaware County.

Sources & Official References

Other rules in Haverford

All Haverford rules

Compare Haverford to another location·View the Pennsylvania building safety overview

Get notified when Fire Sprinkler Requirements in Haverford, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.