Sherman, TX Building Safety: Fire Sprinkler Requirements (2026)
Key Facts
- Deleted provision
- IRC Section R313.2, one- and two-family sprinklers
- Code edition
- 2021 International Residential Code
- Fire code sprinkler rule
- Section 903.2 as amended, new buildings
- Riser room minimum
- 36 square foot, 6 feet interior dimension
- System alterations
- Permit from the fire code official
- Fire safety fine ceiling
- $2,000.00 under § 1.01.009
Summary
In the City of Sherman, Texas, the residential code amendment in § 3.03.001 deletes Section R313.2 of the 2021 International Residential Code, the automatic fire system requirement for one- and two-family dwellings. Sprinklers for other new buildings are governed by the city's amended Fire Code, Section 903.2, enforced by the fire code official.
The following additions, amendments and/or deletions to the International Residential Code, 2021 edition, are hereby adopted: ... (3) Section R313.2 (One- and two-family dwellings automatic fire systems) shall be deleted.
Full Breakdown
Sherman adopts the 2021 International Residential Code in § 3.02.001 and then edits it in § 3.03.001. Item (3) of that section reads: Section R313.2 (One- and two-family dwellings automatic fire systems) shall be deleted. The effect in the City of Sherman, Texas, is that the model code's sprinkler mandate for one- and two-family dwellings is removed from the city's version of the residential code. The same section deletes Part VIII, Electrical, chapters 34 through 43, and requires an engineered shear wall plan and a form board survey for new residential buildings and additions.
Commercial and other buildings are handled in the Fire Prevention Code, article 3.04, which amends the 2021 International Fire Code. Section 3.04.001 rewrites Section 903.2 to say that approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in Sections 903.2.1 through 903.2.12, and it adds local occupancy rules. Ambulatory care facilities need a system throughout the floor when four or more care recipients are incapable of self-preservation. Laboratories testing lithium-ion or lithium metal batteries need one throughout the fire areas used for that work.
The code also regulates the equipment itself. Alterations to a fire protection system must be approved and permitted by the fire code official, and hydrostatic testing and inspection can be required before final acceptance (Section 901.4). Sprinkler riser rooms must have a minimum size of 36 square foot with a minimum interior wall to wall dimension of 6 feet, with an additional minimum of 9 square foot per additional riser, and must hold only fire protection equipment (Sections 901.4.7 and 901.4.7.5). When a required system is out of service, the fire department and fire code official must be notified immediately, and a fire watch can be required (Section 901.7). Where chapter provisions conflict, § 3.02.001(b) says the more restrictive provision controls.
Violations & Fines
Violations of the building codes article and the codes adopted article are punishable under § 1.01.009 through §§ 3.01.008 and 3.02.002. The general fine is up to $500.00, rising to a ceiling of $2,000.00 for rules governing fire safety, and each day a violation continues is a separate offense. The city can also pursue abatement, injunctive relief and revocation of licenses or permits.
Frequently Asked Questions
Does Sherman require sprinklers in new single-family homes?
Where do Sherman's fire code amendments live?
Who approves changes to an existing sprinkler system?
How big must a sprinkler riser room be?
Sources & Official References