West Des Moines, IA Building Safety: Fire Sprinkler Requirements (2026)
Key Facts
- Single-family exemption threshold
- Under 8,000 sq ft total floor space
- Townhouse/two-family threshold
- Under 12,000 sq ft, fire-rated walls
- Governing code
- IRC §R313.1/R313.2 as amended
- Documentation required
- Square footage shown on submitted plans
- Enforcing agency
- Building Division, Development Services
Summary
In the City of West Des Moines, a single-family dwelling under 8,000 square feet of floor space, including the garage and covered porches and decks, is exempt from the automatic residential fire sprinkler mandate under the amended International Residential Code, and townhouse or two-family buildings under 12,000 square feet with fire-rated common walls get a similar exception.
8-2A-12: BUILDING PLANNING (CHAPTER 3 OF THE IRC): ... Amend Section R313.2 of the IRC (One- and two-family dwellings automatic fire sprinkler systems) by deleting the title and replacing it with the following: (Single Family dwellings automatic fire sprinkler systems) Further Amend Section R313.2 of the IRC (Single family dwellings automatic fire sprinkler systems) by adding the following Exception: Exception 2: An automatic residential fire sprinkler system shall not be required for single family dwellings containing less than eight thousand (8,000) square feet of floor space, including the garage, covered decks, covered porches and similar covered areas. Documentation of square footage totals meeting the 8,000 square foot exception shall be provided on the plans by the designer.
Full Breakdown
City Code section 8-2A-12 amends IRC Section R313.2 (Single Family Dwellings Automatic Fire Sprinkler Systems) by adding Exception 2: an automatic residential fire sprinkler system is not required for a single-family dwelling containing less than 8,000 square feet of floor space, counting the garage, covered decks, covered porches and similar covered areas toward that total. The designer must document the square footage totals used to meet the exception directly on the building plans submitted to the Building Division. The same section amends the parallel IRC Section R313.1 (retitled to cover Townhouse and Two-Family Dwelling automatic fire sprinkler systems) with its own Exception 2, exempting a multi-unit building under 12,000 square feet from the sprinkler mandate where each unit runs from foundation to roof with open yard or public way on at least two sides and the shared walls between units carry either two one-hour fire-resistance-rated wall assemblies or a single two-hour rated assembly.
Above these square footage thresholds, or where the fire-separation and open-yard conditions are not met, the base IRC sprinkler mandate applies and a residential fire sprinkler system must be installed and inspected before occupancy. The Building Division, part of Development Services, reviews the plan documentation and inspects sprinkler installations where the exception does not apply.
Violations & Fines
Occupying a single-family home of 8,000 square feet or more, or a qualifying multi-unit townhouse or two-family building of 12,000 square feet or more, without the required automatic fire sprinkler system, or submitting inaccurate square footage documentation to claim an exception under section R313.1 or R313.2, is a violation of Chapter 8, Article A and a municipal infraction under Title 1, Chapter 4, Section 1, carrying a civil penalty of up to $750.00 per violation and up to $1,000.00 for a repeat violation, plus a Building Official order to install the required system before a certificate of occupancy issues.
Frequently Asked Questions
Does a new single-family house in West Des Moines need fire sprinklers?
What size floor space triggers the sprinkler exception for a townhouse building?
Sources & Official References
Other rules in West Des Moines
Compare West Des Moines to another location·View the Iowa building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.