Monterey, CA Building Safety: Plumbing Permits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Adopted code
2025 California Plumbing Code
Backwater valve trigger
Trap outlet under 2 feet above manhole rim
Required equipment
Backwater valve, relief vent, cleanout
Cleanout placement
Within 1 foot of ground surface
Enforcing officer
Building Official orders plug/cap
Penalty
Misdemeanor under § 9-66

Summary

Monterey enforces the 2025 California Plumbing Code for permitted plumbing work, adopted at Monterey City Code § 9-0.1, and adds a local backwater-valve rule at § 9-2: any fixture trap sitting less than two feet above the nearest upstream manhole rim must have an approved backwater valve, relief vent and cleanout installed in the building sewer.

Except as amended by this chapter and Chapter 13 of this code, the following model codes, sometimes referred to in this Chapter as “technical codes,” are hereby adopted and incorporated by reference as if fully set forth herein: ... 5.2025 California Plumbing Code; ... Section 710.1.1 is added to read as follows:710.1.1 Backwater Valves. In every case where the outlet of a trap for a plumbing fixture is installed or located at an elevation which is less than two feet (2’) above the rim of the nearest manhole uphill from the point of connection of the building sewer to the public sewer in any new or existing drainage system, approved types of backwater valve, relief vent and cleanout shall be installed in the building sewer at the point of lowest elevation of the ground surface of the building site outside of the building or at such other location as is permitted by the Building Official, providing that any such location, the elevation of the ground surface is not less than two feet (2’) below the lowest trap outlet served by the building sewer.

View official code

Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance 3721, passed July 7, 2026).

Full Breakdown

1 alongside the city's other technical codes. The City adds one significant local amendment at § 9-2: wherever a plumbing fixture's trap outlet sits less than two feet above the rim of the nearest manhole uphill from where the building sewer connects to the public sewer, in either a new or an existing drainage system, the property must have an approved backwater valve, relief vent and cleanout installed in the building sewer at the lowest point of the ground surface outside the building, or at another location the Building Official permits, so long as that alternate location is still at least two feet below the lowest served trap outlet.

' Once the Building Official identifies such a site, the code empowers the office to order the outlet plugged, capped, or brought into compliance immediately. Because low-lying fixture traps are common near Monterey's flat, near-sea-level neighborhoods, this backwater-valve rule is one of the plumbing permit reviewer's standard checks. 06, with each day of continued violation a separate offense.

Violations & Fines

Installing or maintaining a low-lying fixture trap without the required backwater valve, relief vent and cleanout under Monterey City Code § 9-2 is a misdemeanor under § 9-66, fined per § 1-1.06. The Building Official can order an out-of-compliance outlet plugged, capped or corrected immediately, and each day of continued violation is a separate offense enforceable through the City's Administrative Remedies Ordinance or as a public nuisance.

Frequently Asked Questions

Does Monterey require backwater valves on plumbing permits?
Yes. Monterey City Code § 9-2 requires an approved backwater valve, relief vent and cleanout whenever a fixture trap outlet sits less than two feet above the rim of the nearest upstream manhole, in both new construction and existing drainage systems.
What plumbing code does Monterey enforce?
The 2025 California Plumbing Code, adopted by reference at Monterey City Code § 9-0.1, governs permitted plumbing installations citywide, with the city's own backwater-valve amendment at § 9-2 layered on top for low-lying fixture traps near the sewer connection.
What happens if my property has an unprotected low trap outlet?
The code calls an installation lacking the required backwater valve 'dangerous, unsanitary and a menace to life, health and property,' and once the Building Official finds one, the office can order it immediately plugged, capped, or brought up to the § 9-2 standard.

Sources & Official References

Other rules in Monterey

All Monterey rules

California rules heatmap·Compare Monterey to another location·View the California building safety overview

Get notified when Plumbing Permits in Monterey, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Plumbing Permits in Nearby Cities

How other cities in Monterey County handle plumbing permits.

Salinas, CA
Some Restrictions