Westminster, CO Building Setbacks & Zoning: Setback Rules (2026)
Key Facts
- Front setback, RE/R1/RA/R2
- 30 feet
- Front setback, R3/R4/T1
- 25 feet
- Interior side setback
- 5-7 feet depending on zone
- Rear setback, all residential zones
- 20 feet
- Administrative reduction allowed
- Up to 10%
Summary
Westminster's Density Schedule sets a 30-foot front setback in the RE, R1 and RA districts, dropping to 25 feet in R3, R4 and T1. Interior side setbacks run 5 to 7 feet, with a 12-to-20-foot combined-sides minimum, and rear setbacks are a flat 20 feet across every residential district. The City Manager may shave up to 10 percent off any setback.
DENSITY SCHEDULE RE R1 RA R2 R3 R4 R5 T1 B1 C1&C2 M1 O1 Minimum Front Setback — Principal Building: 30′ 30′ 30′ 30′ 25′ 25′ (d) 25′ 30′ 30′ 30′ 30′ Minimum Side Setback; Interior Lot — Principal Building: 7′ 5′ 5′ 5′ 5′ 5′ (d) 5′ (b) (b) 40′ 30′ Minimum Rear Setback — Principal Building: 20′ 20′ 20′ 20′ 20′ 20′ (d) 20′ (c) (c) (c) 30′
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 12).
Full Breakdown
Section 11-4-5, the Density Schedule, sets minimum building setbacks for every zoning district except Planned Unit Development. The Minimum Front Setback for a principal building is 30 feet in RE, R1, RA, R2, B1, C1, C2, M1 and O1, but drops to 25 feet in R3, R4, and T1. Minimum interior side setbacks range from 5 feet (R1, RA, R2, R3, R4, T1) to 7 feet (RE), while B1 and C1 use an adjacency rule requiring the same setback as any adjoining residential district under footnote (b).
The minimum combined total of both side setbacks ranges from 12 feet in R2, R3, R4 and T1 up to 20 feet in RE. Corner-lot side setbacks facing a side street run 15 feet across every residential district, and reverse-corner-lot side setbacks climb to 30 feet in RE, R1, RA and R2, or 25 feet in R3, R4 and T1. The rear setback for a principal building is a uniform 20 feet in every residential district from RE through T1, and 30 feet in O1; commercial districts B1, C1 and C2 instead use footnote (c), 20 feet from the center of an alley or the rear lot line, whichever is less.
Section 11-4-5(B) lets the City Manager or a designee grant up to a 10-percent reduction in setback requirements (or increase in height limits) if the change would not significantly alter the site plan or harm adjoining properties. Section 11-4-6(D) adds refinements: architectural features like cornices and eaves may extend up to 4 feet into a setback, ground-level decks may extend into a setback entirely, and fire escapes may project up to 6 feet.
Violations & Fines
Building within a required setback without an approved reduction, or exceeding the permitted 10-percent administrative adjustment under Section 11-4-5(B), is a zoning code violation subject to code enforcement and can block issuance of a certificate of occupancy. Encroachments beyond the architectural-feature exceptions in Section 11-4-6(D) require a variance or plan amendment before construction proceeds.
Frequently Asked Questions
What is the minimum front yard setback in Westminster's R1 district?
Can Westminster reduce my required setback?
How close can I build to my rear lot line in a Westminster residential zone?
Sources & Official References
Other rules in Westminster
Compare Westminster to another location·View the Colorado building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.