Westminster, CO Building Setbacks & Zoning: Structure Height Limits (2026)
Key Facts
- RE/R1/RA/R2/O1 height cap
- 25 feet, principal building
- R3/R4/T1 height cap
- 35 feet, principal building
- Accessory building cap
- 15 feet (35 feet in O1)
- B1/C1&C2/M1 height cap
- 65 feet
- Administrative increase allowed
- Up to 10%
Summary
Westminster caps principal residential buildings at 25 feet in the RE, R1, RA, R2 and O1 districts, rising to 35 feet in R3, R4 and T1. Accessory buildings top out at 15 feet in every residential zone. Business and industrial districts B1, C1&C2 and M1 allow up to 65 feet, and the City Manager may add up to 10 percent more.
DENSITY SCHEDULE RE R1 RA R2 R3 R4 R5 T1 B1 C1&C2 M1 O1 Maximum Building Height — Principal Building: 25′ 25′ 25′ 25′ 35′ 35′ (d) 35′ 65′ 65′ 65′ 25′ Maximum Building Height — Accessory Building 15′ 15′ 15′ 15′ 15′ 15′ 15′ 15′ 15′ 15′ 15′ 35′
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 12).
Full Breakdown
5 to 22 dwelling units per acre. Commercial and industrial districts B1, C1&C2, and M1 allow principal buildings up to 65 feet. Accessory building height is capped at 15 feet in every district except O1, where it rises to 35 feet, matching the taller principal-building allowance there. A separate row limits non-building structures, such as towers or antennas that are not habitable buildings, to 25 feet in RE, R1, RA, R2, R3 and R4, and 35 feet in T1, B1, C1&C2, M1 and O1. For PUD-zoned property where the Preliminary or Official Development Plan has not set its own maximum, Section 11-4-5(C) supplies fallback heights: 40 feet for a residential principal building, 65 feet for a non-residential or mixed-use principal building, 15 feet for a residential accessory building, and 35 feet for a non-residential accessory building or non-building structure.
Section 11-4-5(B) allows the City Manager or a designee to grant up to a 10-percent increase in the height limit if the increase would not significantly change the site plan or create a significant negative impact on adjoining properties. Section 11-4-6(L) specifies that building height is measured under the City's currently adopted Building Code.
Violations & Fines
Constructing a principal or accessory building above its district's Density Schedule height limit, without a granted 10-percent administrative increase under Section 11-4-5(B) or an approved PUD development plan allowance, is a zoning violation that blocks building permit sign-off and can require the structure to be shortened or removed.
Frequently Asked Questions
How tall can I build a house in Westminster's R1 district?
What is the height limit for a shed or detached garage in a Westminster residential zone?
Can Westminster allow a taller building than the zoning table permits?
Sources & Official References
Other rules in Westminster
Compare Westminster to another location·View the Colorado building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.