Weston, FL Building Setbacks & Zoning: Setback Rules (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

R1 front/rear/side/street-side
20/10/5/20 ft.
R3 side setback
7.5 ft.
Mechanical equipment encroachment
up to 60 in. into setback
Generator encroachment
up to 50% of setback
Patio/deck setback
reducible to 5 ft.
Roof overhang
18 in. (24 in. if setback ≥10 ft.)

Summary

In the City of Weston, Florida, single-family setbacks run by zoning district under the dimension table in Weston Code of Ordinances section 124.47(A); an R1 lot, for example, must keep a 20-foot front, 10-foot rear, 5-foot side, and 20-foot street-side setback, with limited encroachments allowed for mechanical equipment, patios, and roof overhangs.

Front Rear Side Street Side ... R1 4,000 25 ft. 35 ft. 20 ft. 10 ft. 5 ft. 20 ft. ... Every part of every required yard Setback shall be open and unobstructed except as hereinafter provided or as otherwise permitted in this Code . ... Mechanical equipment, including, but not limited to air conditioning units, Irrigation and swimming pool equipment, may not project over 60 inches from the Building wall into a required minimum yard Setback , except generators. Generators may encroach no more than 50% from the building wall into a required minimum rear or side yard Setback and shall be prohibited within five feet of the adjacent front plane of the house. ... Roof overhangs may not project more than 18 inches into a required yard (24 inches if the distance to the property line is ten feet or greater).

Full Breakdown

Section 124.47(A)'s dimension table sets front, rear, side, and street-side setbacks for each single-family zoning district. R1 requires 20 feet front, 10 feet rear, 5 feet side, and 20 feet street side; R2 and R3 require 20 feet front and 15 feet rear, with side setbacks of 5 feet (R2) or 7.5 feet (R3); R4 requires 25 feet front, 15 feet rear, and a side setback of 7.5 feet that drops to 5 feet on lots under 60 feet wide; RE requires 25 feet front, 15 feet rear, and 10 feet side on its larger lots.

Multi-family districts MF1 through MF4 scale up front and rear setbacks with building height and unit count, reaching 45-foot front and 40-foot rear setbacks in MF3 and MF4. Section 124.47(C) then defines what may intrude into those required yards. Mechanical equipment, including air conditioning units, irrigation equipment, and pool equipment, may project up to 60 inches from the building wall into a required yard setback; generators are treated more strictly, capped at encroaching no more than 50 percent of the setback from the wall and barred within five feet of the front plane of the house, with all generator fuel tanks required below ground.

Unenclosed, unroofed patios or decks may come within five feet of a plot line or easement under section 124.47(C)(2), and roof overhangs may project 18 inches into a required yard, or 24 inches where the setback is at least 10 feet. Section 124.48(C) additionally lets a legal nonconforming setback that predates June 18, 2012 be preserved as the plane of the house for additions and rebuilds.

Violations & Fines

Building within a required setback, over-encroaching with mechanical equipment or a generator, or ignoring the roof-overhang limit is a violation Weston's contracted Building Division flags at plan review and Code Compliance enforces under Chapter 31. With no chapter-specific fine, the general penalty at section 2.99 applies, up to $1,000 per day for a first offense and up to $5,000 per day for a repeat offense.

Frequently Asked Questions

What is the side setback for a Weston, FL single-family home?
It depends on the zoning district: section 124.47(A) sets a 5-foot side setback in R1 and R2, 7.5 feet in R3, and 7.5 feet in R4 (reduced to 5 feet on lots under 60 feet wide), plus 10 feet in the larger-lot RE district.
Can my air conditioner sit inside the setback in Weston?
Yes, within limits. Section 124.47(C)(1) allows mechanical equipment such as air conditioning and pool equipment to project up to 60 inches from the building wall into a required yard setback.
Can I keep my existing setback if my house predates the current rule?
Often yes for additions. Section 124.48(C) lets a single-family or duplex structure that already had a lesser setback as of June 18, 2012 use the existing plane of the house as the required setback for additions.

Sources & Official References

Other rules in Weston

All Weston rules

Florida rules heatmap·Compare Weston to another location·View the Florida building setbacks & zoning overview

Get notified when Setback Rules in Weston, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Setback Rules in Nearby Cities

How other cities in Broward County handle setback rules.

Hollywood, FL
Some Restrictions
Pompano Beach, FL
Some Restrictions
Miramar, FL
Some Restrictions
Pembroke Pines, FL
Some Restrictions