Weston, FL Building Setbacks & Zoning: Lot Coverage Limits (2026)
Key Facts
- Max impervious area, SF lot
- 60% (§ 124.36(G))
- Max enclosed accessory size
- 25% of main use space
- AE district plot coverage
- 25% of plot area
- Accessory setbacks
- same as principal building
- Rear-half accessory setback reduction
- to 5 ft. side/rear
Summary
In the City of Weston, Florida, impervious surface on a single-family residential lot is capped at 60 percent under Weston Code of Ordinances section 124.36(G), and enclosed accessory structures such as cabanas, sheds, or in-law quarters may not exceed 25 percent of the space occupied by the main house under section 124.36(F).
Enclosed Accessory Uses , such as but not limited to cabanas, mother-in-law quarters, patios, storage sheds, and recreational Structures may occupy no more than a total of 25% of the space occupied by the main permitted Use and shall have the same roof profile, materials and color and exterior finish, materials, color and architectural style as the main Structure . ... The maximum Impervious Area on a Single-Family residential Lot shall not exceed 60%.
Full Breakdown
Weston's Accessory Use Regulations chapter sets two related coverage limits for single-family lots. Section 124.36(G) caps the maximum impervious area, driveways, patios, pool decks, structures, and other hardscape, at 60 percent of a single-family residential lot; the remaining 40 percent must stay pervious for stormwater to infiltrate rather than run off. Section 124.36(F) separately limits enclosed accessory uses, listed as including cabanas, mother-in-law quarters, patios, storage sheds, and recreational structures, to no more than 25 percent of the floor space occupied by the main permitted use, and requires the accessory structure to match the main structure's roof profile, materials, color, and architectural style.
A parallel, district-specific coverage limit applies in the Agricultural Estate (AE) zoning district: section 124.47(A)(1)(c)4 caps plot coverage there at 25 percent of the plot area for all combined main and accessory buildings and structures, a tighter limit reflecting the district's larger minimum lot sizes and rural character. These coverage rules interact with the setback and encroachment standards in the same title; an over-the-impervious-limit driveway extension or an oversized shed cannot be brought into compliance by shifting it into a setback, since 124.36(H) requires accessory buildings to meet the same setbacks as principal buildings except for narrow reductions on rear-half accessory structures.
A property owner adding a pool deck, a shed, or additional paving must confirm the running total against the 60 percent impervious cap before a building permit will be approved.
Violations & Fines
Exceeding the 60 percent impervious area cap or building an oversized accessory structure beyond the 25 percent limit is flagged at building permit review and enforced afterward by Weston's Code Compliance Division under Chapter 31. Absent a listed chapter fine, the general penalty at section 2.99 applies, up to $1,000 per day for a first violation and up to $5,000 per day for a repeat violation.
Frequently Asked Questions
What is the maximum impervious area allowed on a Weston, FL lot?
How big can a shed be in my Weston backyard?
Does the AE district have a different coverage limit?
Sources & Official References
Other rules in Weston
Florida rules heatmap·Compare Weston to another location·View the Florida building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Lot Coverage Limits in Nearby Cities
How other cities in Broward County handle lot coverage limits.