Skip to main content
CityRuleLookup

Casa Grande, AZ Building Setbacks & Zoning: Structure Height Limits (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Maximum building height
28 feet, R-1 Zone
Same limit in
UR Zone and R-1a Zone tables
Accessory structure standard
Section 17.52.100, not the height table
Exceeding the limit requires
Variance or rezoning approval
Governing table
Table 17.20.150

Summary

Casa Grande Municipal Code Table 17.20.150 caps building height in the R-1 single-family zone at 28 feet, the same ceiling set for the UR and R-1a residential districts, while structures for other principal or conditional uses on an R-1 lot carry their own 20-foot setback under the same table.

Structures for all other 20' 10' 20' 20' principal or conditional uses ... Maximum Building Height: 28 feet.

Full Breakdown

Table 17.20.150, printed under § 17.20.150 of the Casa Grande Municipal Code, sets a maximum building height of 28 feet for the R-1 Single-Family Residential Zone. The height line sits directly beneath the zone's setback schedule, which requires 20-foot setbacks on all four sides for structures for all other principal or conditional uses beyond a standard single-family home, and a uniform 50-foot setback for schools, civic, cultural and religious institutions and their accessory structures over 675 square feet. The same 28-foot ceiling appears in the tables for the neighboring Urban Ranch (UR) Zone under Table 17.20.060 and the R-1a Zone under Table 17.20.240, so Casa Grande applies one height standard across its principal low-density residential districts.

Accessory structures are instead governed by the separate standards in § 17.52.100, not by the principal-building height line in Table 17.20.150. Development in the R-1 Zone must also meet the additional building and performance standards found in Chapters 17.52 through 17.64, as required by § 17.20.170. Any proposed structure that would exceed 28 feet, such as a taller custom home, requires either a variance from the Board of Adjustment or a rezoning approved by the City Council before Planning and Development can issue a building permit.

Violations & Fines

Casa Grande Municipal Code § 1.08.010 makes exceeding the 28-foot height limit without an approved variance a Class II misdemeanor, carrying a fine of up to $750, up to four months in jail, or both. Each day the oversized structure remains in violation counts as a separate offense under the same section.

Frequently Asked Questions

How tall can a house be in Casa Grande's R-1 zone?
Table 17.20.150 of the Casa Grande Municipal Code caps building height at 28 feet in the R-1 Single-Family Residential Zone. This is the same maximum height set for the neighboring Urban Ranch and R-1a zones, so a homeowner cannot build taller without a variance.
Does the 28-foot limit apply to a detached garage or shed?
Accessory structures are governed separately by § 17.52.100 rather than the principal-building height figure in Table 17.20.150, so an accessory building's height standard is set in that section, not by the 28-foot line that applies to the main residence.
What if I want to build taller than 28 feet?
A structure that would exceed the Table 17.20.150 height limit needs either a variance from the Board of Adjustment or a rezoning approved by the City Council before Planning and Development can issue a building permit for it.

Sources & Official References

Other rules in Casa Grande

All Casa Grande rules

Compare Casa Grande to another location·View the Arizona building setbacks & zoning overview

Get notified when Structure Height Limits in Casa Grande, AZ changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.