Santa Ana, CA Building Setbacks & Zoning: Structure Height Limits (2026)
Key Facts
- Zoning district
- R1 (single-family residence)
- Height cap
- 27 feet
- Story cap
- 2 stories
- Measured from
- Lowest adjacent grade
- Planned developments
- Same 27-ft R1 cap applies
Summary
A single-family home in Santa Ana's R1 district can't rise higher than 27 feet or exceed two stories, measured from the lowest adjacent grade to the top of the structure. Planned developments follow the same cap under Section 41-357(b), which imposes no separate height limit of its own for PD projects.
No primary structure shall exceed twenty-seven (27) feet nor two (2) stories in height, as measured from the lowest adjacent grade of the structure to the top of the structure.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 32).
Full Breakdown
Section 41-233 of the Santa Ana Municipal Code sets the building height limit for the R1 (single-family residence) zoning district at 27 feet and two stories, whichever is more restrictive on a given design, a home can't exceed either threshold. The measurement runs from the lowest adjacent grade of the structure to the top of the structure, so a sloped lot's height allowance is anchored to its lowest point rather than an average or the highest point, preventing homes on graded or hillside lots from gaining extra usable height.
This 27-foot cap has been in place since the city's original 1960 zoning ordinance (Ord. No. NS-455) and was last amended in 1991 by Ord. No. NS-2111. The same limit extends beyond the R1 district itself: Section 41-357(b), governing site development standards for Planned Development (PD) projects, states there is no separate structural height limitation for PD projects except as set forth in the R1 district regulations, meaning a planned residential development is held to the identical 27-foot/two-story ceiling unless its conditional use permit specifies otherwise.
The height limit works together with the R1 setback standards (Sections 41-234 through 41-236) and the 35 percent lot coverage cap (Section 41-238) to define the maximum buildable form on any R1 lot.
Violations & Fines
Constructing a primary structure taller than 27 feet or more than two stories as measured from the lowest adjacent grade violates Section 41-233 and, for planned developments, Section 41-357(b); the city can deny final building inspection or issue a code enforcement order requiring the offending portion of the structure to be reduced to conforming height before occupancy is approved.
Frequently Asked Questions
How tall can a house be in Santa Ana's R1 zone?
From where is the 27-foot height measured on a sloped R1 lot?
Does a planned development in Santa Ana get a taller height allowance?
Sources & Official References
Other rules in Santa Ana
California rules heatmap·Compare Santa Ana to another location·View the California building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Structure Height Limits in Nearby Cities