Stonecrest, GA Building Setbacks & Zoning: Structure Height Limits (2026)
Key Facts
- Main building height
- 35 feet in RE, RLG, R-100, R-85, R-75, R-60, MHP
- Infill overlay limit
- 28 feet
- Accessory building height
- 24 feet (N/A in MHP)
- SF measurement point
- Front-door threshold to roof peak
- Fire rebuild exception
- May rebuild to original (pre-fire) height
- Neighborhood-average exception
- Infill lot may match block average if 60%+ exceed limit
Summary
Stonecrest Zoning Ordinance Table 2.2 caps main residential buildings at 35 feet across every single-family district (RE, RLG, R-100, R-85, R-75, R-60, MHP), with 28 feet under the residential infill overlay and 24 feet for accessory buildings. Sec. 5.2.5 sets the measurement method and lists specific height exceptions.
Element RE RLG R-100 R-85 R-75 R-60 MHP RNC * ... Height (maximum) Main building (feet) (Residential infill overlay = 28 feet) 35 35 35 35 35 35 35 * Accessory building (feet) 24 24 24 24 24 24 N/A * ... E.Height requirements.1.The maximum height of a new single-family detached dwelling shall comply with the requirements of Table 2.2.2.The height limitations established in this chapter shall not apply to the following:a.Barns, silos or other similar structures when located on farms; belfries, steeples, cupolas and domes; chimneys; and flagpoles.
Full Breakdown
Zoning Ordinance Sec. 2.2.1, Table 2.2 ("Residential Zoning Districts Dimensional Requirements") sets the maximum height for a main building at 35 feet uniformly across the RE, RLG, R-100, R-85, R-75, R-60 and MHP single-family districts, with a footnote reducing the limit to 28 feet inside the residential infill overlay; accessory buildings are capped at 24 feet in every district except MHP, where the accessory limit is not applicable. Sec. 5.2.5 fixes how height is measured: for single-family detached dwellings, from the front-door threshold to the highest point of the roof, and for all other structures, from average finished grade to the roof beams, deck level or eave-to-ridge average depending on roof type.
The same section carves out several structures from the height cap entirely, including barns and silos on farms, belfries, steeples, cupolas, domes, chimneys, flagpoles, bulkheads, elevator penthouses, rooftop mechanical equipment and water tanks (capped at 25 percent of roof area), permitted telecommunications towers, and rooftop equipment under six feet. A single-family home damaged by fire or another act of nature may be rebuilt to its original height even if that exceeds the district limit, and an infill lot within a subdivision where 60 percent of homes already exceed the height limit may be built to the block's average existing height.
A separate Sec. 5.2.4 transitional height plane restricts commercial and multifamily buildings near single-family districts, requiring the building to step back at a 45-degree angle above 35 feet measured from the applicable setback or buffer line.
Violations & Fines
A structure built above the 35-foot main-building limit (28 feet in the residential infill overlay) or the 24-foot accessory limit without qualifying for one of the Sec. 5.2.5 exceptions or an approved variance is a zoning violation subject to enforcement by Community Development/Code Enforcement under the zoning ordinance's administration and nonconformity provisions (Zoning Ordinance arts. 7-8).
Frequently Asked Questions
How tall can a house be built in Stonecrest's single-family districts?
How is house height actually measured?
Are chimneys and antennas exempt from the height limit?
Can a fire-damaged house be rebuilt taller than today's limit allows?
Sources & Official References
Other rules in Stonecrest
Compare Stonecrest to another location·View the Georgia building setbacks & zoning overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.