Key Facts

Main building height
35 feet in RE, RLG, R-100, R-85, R-75, R-60, MHP
Infill overlay limit
28 feet
Accessory building height
24 feet (N/A in MHP)
SF measurement point
Front-door threshold to roof peak
Fire rebuild exception
May rebuild to original (pre-fire) height
Neighborhood-average exception
Infill lot may match block average if 60%+ exceed limit

Summary

Stonecrest Zoning Ordinance Table 2.2 caps main residential buildings at 35 feet across every single-family district (RE, RLG, R-100, R-85, R-75, R-60, MHP), with 28 feet under the residential infill overlay and 24 feet for accessory buildings. Sec. 5.2.5 sets the measurement method and lists specific height exceptions.

Element RE RLG R-100 R-85 R-75 R-60 MHP RNC * ... Height (maximum) Main building (feet) (Residential infill overlay = 28 feet) 35 35 35 35 35 35 35 * Accessory building (feet) 24 24 24 24 24 24 N/A * ... E.Height requirements.1.The maximum height of a new single-family detached dwelling shall comply with the requirements of Table 2.2.2.The height limitations established in this chapter shall not apply to the following:a.Barns, silos or other similar structures when located on farms; belfries, steeples, cupolas and domes; chimneys; and flagpoles.

Full Breakdown

Zoning Ordinance Sec. 2.2.1, Table 2.2 ("Residential Zoning Districts Dimensional Requirements") sets the maximum height for a main building at 35 feet uniformly across the RE, RLG, R-100, R-85, R-75, R-60 and MHP single-family districts, with a footnote reducing the limit to 28 feet inside the residential infill overlay; accessory buildings are capped at 24 feet in every district except MHP, where the accessory limit is not applicable. Sec. 5.2.5 fixes how height is measured: for single-family detached dwellings, from the front-door threshold to the highest point of the roof, and for all other structures, from average finished grade to the roof beams, deck level or eave-to-ridge average depending on roof type.

The same section carves out several structures from the height cap entirely, including barns and silos on farms, belfries, steeples, cupolas, domes, chimneys, flagpoles, bulkheads, elevator penthouses, rooftop mechanical equipment and water tanks (capped at 25 percent of roof area), permitted telecommunications towers, and rooftop equipment under six feet. A single-family home damaged by fire or another act of nature may be rebuilt to its original height even if that exceeds the district limit, and an infill lot within a subdivision where 60 percent of homes already exceed the height limit may be built to the block's average existing height.

A separate Sec. 5.2.4 transitional height plane restricts commercial and multifamily buildings near single-family districts, requiring the building to step back at a 45-degree angle above 35 feet measured from the applicable setback or buffer line.

Violations & Fines

A structure built above the 35-foot main-building limit (28 feet in the residential infill overlay) or the 24-foot accessory limit without qualifying for one of the Sec. 5.2.5 exceptions or an approved variance is a zoning violation subject to enforcement by Community Development/Code Enforcement under the zoning ordinance's administration and nonconformity provisions (Zoning Ordinance arts. 7-8).

Frequently Asked Questions

How tall can a house be built in Stonecrest's single-family districts?
Table 2.2 of the Zoning Ordinance sets 35 feet as the maximum main-building height in the RE, RLG, R-100, R-85, R-75, R-60 and MHP districts, dropping to 28 feet for lots inside the residential infill overlay.
How is house height actually measured?
Sec. 5.2.5(B) measures single-family detached homes from the front-door threshold to the highest point of the roof, using the top of the subfloor at the designated front door as the threshold reference point.
Are chimneys and antennas exempt from the height limit?
Yes. Sec. 5.2.5(E)(2) exempts belfries, steeples, cupolas, domes, chimneys, flagpoles, elevator penthouses, rooftop mechanical equipment and permitted telecommunications towers from the district height cap.
Can a fire-damaged house be rebuilt taller than today's limit allows?
Sec. 5.2.5(E)(2)(d) lets any single-family home exceeding the current height limit that is damaged by fire or another act of nature be reconstructed to its verifiable original height.

Sources & Official References

Other rules in Stonecrest

All Stonecrest rules

Compare Stonecrest to another location·View the Georgia building setbacks & zoning overview

Get notified when Structure Height Limits in Stonecrest, GA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.