Key Facts

RS 12/9/6, RD 6, RM 12/24 max height
35 feet
RM 36 max height
50 feet
RMH (manufactured housing) max height
20 feet
Governing table
TMC 1106.0101 dimensional standards
Height defined at
TMC 1116.0140
Table last amended
Ord. 533-24, passed 10-23-24

Summary

Toledo caps residential building height by zoning district: 35 feet in the RS 12, RS 9, RS 6, RD 6, RM 12 and RM 24 districts, 50 feet in RM 36, and 20 feet in manufactured housing (RMH) districts, per the Zoning Code's dimensional standards table.

1106.0101 Residential Districts. Unless otherwise expressly stated, all buildings in Residential (R) Districts must comply with the following standards, as well as all other applicable standards of this Zoning Code. (Ord. 170-04. Passed 3-23-04; Ord. 346-10. Passed 6-22-10; Ord. 229-13. Passed 4-30-13; Ord. 533-24. Passed 10-23-24.) Standard RS 12 RS 9 RS 6 RD 6 RM 12 RM 24 RM 36 RMH ... Maximum Height (feet) 35 35 35 35 35 35 50 20

Source: Toledo Zoning CodeView official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-105: Complete to June 30, 2026).

Full Breakdown

0101. The table lists a "Maximum Height (feet)" row applying across all eight residential district types: RS 12, RS 9, RS 6, RD 6, RM 12, RM 24, RM 36 and RMH. Detached-house, attached-house, duplex and multi-dwelling districts from RS 12 through RM 24 are capped at 35 feet. The RM 36 high-density multi-dwelling district allows up to 50 feet. Manufactured housing park district (RMH) is capped at just 20 feet, well below the standard residential districts, reflecting the lower-profile structures typical of manufactured housing.

The same section applies the standards "unless otherwise expressly stated," meaning any more specific provision elsewhere in the Zoning Code controls over this table. 0140: the vertical distance from grade to the highest point of the coping of a flat roof, to the deck line of a mansard roof, or to the mean height level between eaves and ridge for gable, hip and gambrel roofs. That definitional section was last amended by Ord. 158-18, passed April 24, 2018. The dimensional standards table itself was most recently amended by Ord.

533-24, passed October 23, 2024, showing the city continues to actively revise these residential limits. Property owners planning additions, dormers, or new construction that approach these ceilings should confirm their specific district designation before finalizing plans, since exceeding the cap triggers the variance process rather than an as-of-right building permit.

Violations & Fines

Construction exceeding the applicable district height cap without an approved variance is a Zoning Code violation, enforced through the Division of Building Inspection's plan review and permitting process. A project that does not conform cannot receive a building permit unless the owner first obtains a variance from the Board of Zoning Appeals. Building without a valid permit, or building beyond approved plans, exposes the owner to stop-work orders and required remediation to bring the structure into compliance with the district's height limit.

Frequently Asked Questions

How tall can I build a house in a Toledo RS 6 district?
Up to 35 feet, measured under TMC 1116.0140 from grade to the highest point of a flat roof's coping, the deck line of a mansard roof, or the mean height between eaves and ridge for gable, hip and gambrel roofs. This applies to detached houses and all other development in RS 6 per Section 1106.0101.
Is the height limit the same in every Toledo residential district?
No. RS 12, RS 9, RS 6, RD 6, RM 12 and RM 24 are all capped at 35 feet, RM 36 allows 50 feet, and manufactured housing park district RMH is capped at 20 feet, per the Section 1106.0101 dimensional standards table.
What happens if a new home exceeds the district height cap?
The Division of Building Inspection will not issue a building permit for plans that exceed the applicable maximum height unless the Board of Zoning Appeals grants a variance. Building beyond the limit without one risks a stop-work order and required correction.

Sources & Official References

Other rules in Toledo

All Toledo rules

Compare Toledo to another location·View the Ohio building setbacks & zoning overview

Get notified when Structure Height Limits in Toledo, OH changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.