Height Limits

Fences in most Broomfield zone districts top out at six feet, rising to eight feet along state highways or in business and industrial districts, while front-yard fences in estate and lower-density residential districts are limited to ornamental fencing no taller than two and a half feet. Section 17-32-140(A)-(C) sets the tiers.

Broomfield Fence Height Limits

Some Restrictions

Broomfield Municipal Code § 17-32-140(A)-(C)

(A)No fence in any district shall exceed six feet in height, except:(1)As necessary to comply with subsection (F) of this section concerning the enclosure of outdoor swimming pools;(2)Fences adjacent to the state highways may be up to eight feet in height;(3)Fences in the B-1, B-2, I-1, I-2, and I-3 districts may be up to eight feet in height except as required in paragraph (4) below; and ... (...

Fence Permit Requirements

Broomfield requires a building permit for any fence taller than thirty inches. Fences at or under thirty inches are specifically exempted from the permit requirement, though the work still must not violate any other city code provision.

Broomfield Fence Height Permit Threshold

Light Restrictions

Broomfield Municipal Code § 15-03-070(A),(B)

(A)Required. ... Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure ... shall first make application to the building official and obtain the required permit. (B)Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done...

Retaining Walls

Broomfield exempts retaining walls of three feet or less, measured from the bottom of the footing to the top, from needing a building permit, unless the wall supports a surcharge or impounds flammable liquids. Taller walls, or any wall carrying extra load, require a permit and city review.

Broomfield Retaining Wall Permit Height Rule

Some Restrictions

Broomfield Municipal Code § 15-03-070(B)

(B)Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following: Building: 1.Retaining walls that are three feet (1,219 mm) or less in height measured from t...

Material Restrictions

Electrified, razor wire, and barbed wire fences are prohibited across every Broomfield zone district, with narrow carve-outs. Section 17-32-140(G) sets the ban, while (H) allows limited barbed wire on industrial screening fences and (I) allows some barbed wire and internal electric fencing on RR-district lots.

Broomfield Barbed and Electric Fence Ban

Significant Restrictions

Broomfield Municipal Code § 17-32-140(G)-(I)

(G)Electrified, razor wire, and barbed wire fences are prohibited in all zone districts, except as provided in subsection (H) and (I) below.(H)Fences in an I-1 or I-2 districts: ... (2)May include up to four strands of barbed wire. This barbed wire must be a minimum of six feet and a maximum of eight feet from the ground. The barbed wire segment may be placed at a forty-five-degree angle.(I)Fen...