9 verified building safety rules for Lenexa, Kansas, sourced directly from the municipal code and official government pages.

Verified from official government sources

Elevator Maintenance

In the City of Lenexa, Kansas, it is unlawful to operate any elevator, dumbwaiter, escalator or moving walk without a current certificate of inspection from a Qualified Elevator Inspector. Section 4-8-D-17 requires maintenance to ASME A17.1 and the latest certificate displayed in the car or available at the operator's office.

Lenexa Elevator Inspection and Maintenance Rules

Some Restrictions

Lenexa City Code § 4-8-A-22; § 4-8-D-17

3009.1 Certificates of Inspection Required. It shall be unlawful to operate any elevator, dumbwaiter, escalator, or moving walk without a current certificate of inspection provided by a Qualified Elevator Inspector who is certified by the National Association of Elevator Safety Authorities or other similar certification from another nationally recognized organization. ... 606.1 General. Elevato...

Fire Sprinkler Requirements

In the City of Lenexa, Kansas, Section 4-8-C-9 requires an approved automatic fire sprinkler system in new townhouses consisting of three or more connected dwellings. Additions and alterations to existing townhouses that have no residential sprinkler system are exempt from the requirement.

Lenexa Townhouse Fire Sprinkler Requirement

Significant Restrictions

Lenexa City Code § 4-8-C-9

R313.1 Townhouse Automatic Fire Sprinkler Systems: An approved automatic fire sprinkler system in accordance with the International Building Code as adopted and amended by the City of Lenexa shall be installed in new townhouses consisting of three or more connected dwellings. Exception: An automatic fire sprinkler system shall not be required where additions or alterations are made to existing ...

Childcare Center Rules

In the City of Lenexa, Kansas, every limited, general, or commercial daycare needs a State license, permits from the Department of Community Development, and a City business license. A general daycare in a residential or agricultural district gets a 10-year special use permit, and in-home providers must live on site with no more than one outside employee.

Lenexa Daycare Zoning and Licensing Rules

Significant Restrictions

Lenexa City Code § 4-1-B-23-E

Daycare: The following supplementary use standards shall apply to daycare (limited, general and commercial) uses, as indicated (see Section 4-3-C-2 for definitions): Licensing: Daycare shall: Be licensed with the State; Obtain required permits from the Department of Community Development; and Obtain a City business license. Duration Of Permits: The initial special use permit for a general dayca...

Door Locking Hardware

In the City of Lenexa, Kansas, Section 4-8-A-19 adds physical security rules for dwelling units. Exterior doors need a single cylinder deadbolt with a one inch projection that penetrates at least three-fourths inch, and strike plates must be 18 gauge metal fastened with three inch screws.

Lenexa Exterior Door Lock and Hardware Standards

Some Restrictions

Lenexa City Code § 4-8-A-19

1010.4.4 Door hardware. Exterior door hardware shall comply with Sections 1010.4.4.1 through 1010.4.4.5. ... 1010.4.4. ... 2 Strike plates. Exterior door strike plates shall be a minimum of 18 gauge metal with four offset screw holes. Strike plates shall be attached to wood with not less than three inch (3") screws, which shall have a minimum of one inch (1") penetration into the nearest stud. ...

Carbon Monoxide Detectors

In the City of Lenexa, Kansas, one- and two-family dwellings and townhouses licensed as rentals under Chapter 2-16 must be equipped with carbon monoxide alarms as the Code requires for new construction. Section 4-8-C-11 of the Lenexa City Code amends IRC R315.2.3 so the requirement follows the rental license.

Lenexa KS Carbon Monoxide Alarm Rules for Rentals

Some Restrictions

Lenexa City Code § 4-8-C-11

Section R315.2.3 of the International Residential Code is hereby amended to read as follows: ... R315.2.3 Existing Buildings. All one- and two-family dwellings and townhouses which are licensed pursuant to the Residential Rental Licensing provisions set forth in Chapter 2-16 of the Lenexa City Code shall be equipped with carbon monoxide alarms as required by this Code for new construction.

Building Permits

In the City of Lenexa, Kansas, Section 4-8-A-4 requires any owner or agent who builds, enlarges, alters, repairs, moves, demolishes or changes the occupancy of a structure to first apply to the Building Official and obtain a permit. One-story detached sheds of 120 square feet or less are exempt.

Lenexa Building Permit Requirements

Some Restrictions

Lenexa City Code § 4-8-A-4

105.1 Required. Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical, plumbing, fire alarm, fire detection, automatic fire suppression, or LP gas system, the installation of which is regulated by t...

Electrical Permits

The City of Lenexa, Kansas adopts the 2017 National Electrical Code, excluding Article 80, in Section 4-8-I-1. Electrical permits run through Sections 101 through 116 of the International Building Code, and the Building Official in Community Development issues them.

Lenexa KS Electrical Permits and Adopted NEC

Some Restrictions

Lenexa City Code § 4-8-A-2, § 4-8-I-1, § 4-8-I-2

101.4.8 Electrical. The provisions of the National Electric Code shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto. Whenever the ICC Electrical Code is referenced, it shall mean the National Electrical Code, as adopted in Section 4-8-I-1. ... The National Electrical Code (NEC), ...

Plumbing Permits

The City of Lenexa, Kansas adopts the 2018 International Plumbing Code by reference in Section 4-8-F-1 and sends all plumbing permit administration to Chapter 1 of the International Building Code. Applicants deal with the Building Official in the Building Services Division of Community Development.

Lenexa KS Plumbing Permits and Adopted Plumbing Code

Some Restrictions

Lenexa City Code § 4-8-F-1, § 4-8-F-2, § 4-8-F-3

The International Plumbing Code (IPC), 2018 Edition, (fifth printing), including Appendixes B, C, D, and E published by the International Code Council, Inc., 4051 West Flossmoor Road, Country Club Hills, IL 60478-5795, hereafter referred to as the Plumbing Code, are hereby adopted by reference and made a part of this Chapter and Article save and except such parts or portions thereof as are spec...

Building Inspections

In the City of Lenexa, Kansas, permitted work must pass required inspections, and under Section 4-8-A-7 no new building can be occupied until the Building Official issues a certificate of occupancy. For houses, duplexes, townhomes and minor work, an approved final inspection closes the permit.

Lenexa Building Inspections and Certificate of Occupancy

Some Restrictions

Lenexa City Code § 4-8-A-7

111.1 Use and Occupancy. No new building or structure shall be used or occupied, and no change in the existing occupancy classification of an existing building or structure or portion thereof shall be made, and no re-occupancy of existing buildings or tenant spaces shall occur until the Building Official has issued a certificate of occupancy therefore as provided herein. ... Exception: For sing...