Lenexa, KS Building Safety: Door Locking Hardware (2026)
Key Facts
- Deadbolt projection
- 1 inch minimum, penetrating 3/4 inch minimum
- Strike plate
- 18 gauge metal, four offset screw holes
- Strike plate screws
- 3 inch screws, 1 inch into the stud
- Steel door thickness
- 24-gauge minimum
- Wood door thickness
- Solid core, 1-3/4 inches minimum
- Entry door viewer
- Field of view of at least 180 degrees
- Code section
- Lenexa City Code 4-8-A-19
Summary
In the City of Lenexa, Kansas, Section 4-8-A-19 adds physical security rules for dwelling units. Exterior doors need a single cylinder deadbolt with a one inch projection that penetrates at least three-fourths inch, and strike plates must be 18 gauge metal fastened with three inch screws.
1010.4.4 Door hardware. Exterior door hardware shall comply with Sections 1010.4.4.1 through 1010.4.4.5. ... 1010.4.4. ... 2 Strike plates. Exterior door strike plates shall be a minimum of 18 gauge metal with four offset screw holes. Strike plates shall be attached to wood with not less than three inch (3") screws, which shall have a minimum of one inch (1") penetration into the nearest stud. ... 1010.4.4.3 Locks. Exterior doors shall be provided with a locking device complying with all of the following: Single Cylinder Deadbolt shall have a minimum projection of one inch (1"). The deadbolt shall penetrate at least three-fourths inch (3/4") The cylinder shall have a twist-resistant, tapered hardened stell cylinder guard. Bolt assembly (Bolt housing) unit shall be of single piece construction.
Full Breakdown
The City of Lenexa, Kansas, adds Section 1010.4 to the International Building Code through Section 4-8-A-19. Its stated purpose is to set minimum standards that incorporate physical security so dwelling units resist unlawful entry, and it applies to all new structures and to alterations, additions and repairs as stipulated in the International Existing Building Code. The rules reach every swinging door that gives access into a dwelling unit of a residential building or an attached garage, including the door from the garage into the dwelling, but not vehicular access doors.
The hardware standard is in 1010.4.4. Locks must include a single cylinder deadbolt with a minimum projection of one inch that penetrates at least three-fourths inch, a twist-resistant, tapered hardened steel cylinder guard, and a bolt housing of single piece construction. Strike plates must be at least 18 gauge metal with four offset screw holes, attached to wood with screws of not less than three inches that penetrate at least one inch into the nearest stud. Hinges on exterior swinging doors take at least two 3 inch screws penetrating at least one inch into the wall structure, and out-swinging doors need a mechanical interlock so the door cannot be removed from outside. Main entry doors must let the occupant see outside without opening the door, through a viewer with a field of view of at least 180 degrees or through windows or view ports.
The door itself is regulated too. Exterior wood doors must be solid core at least 1-3/4 inches thick, steel doors at least 24-gauge, and fiberglass doors need a skin of at least one-sixteenth inch with reinforcement at the deadbolt. The inactive leaf of double doors needs flush bolts with at least one inch of engagement, and sliding glass doors need a secondary locking device, either a metal pin or a surface mounted bolt. Door frames must be installed before the rough-in inspection. The enforcing authority can approve an alternate material or method that is at least equivalent in burglary resistance and safety (1010.4.7).
Violations & Fines
Section 4-8-A-9 makes it unlawful to build or alter a structure in conflict with the permit, approved plans or any Chapter 4-8 provision. Penalties come from Section 1-1-C-3: a fine of not more than $2,500, imprisonment for not more than one year, or both, and each day is a separate offense. In practice the Building Official can withhold approval at inspection until the door hardware meets Section 4-8-A-19.
Frequently Asked Questions
What deadbolt does Lenexa require on exterior doors?
What are Lenexa's strike plate requirements?
Do the Lenexa door security rules apply to my existing house?
Does Lenexa require a peephole or door viewer?
Sources & Official References
Other rules in Lenexa
Compare Lenexa to another location·View the Kansas building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Door Locking Hardware in Nearby Cities
How other cities in Johnson County handle door locking hardware.