Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Deadbolt projection
1 inch minimum, penetrating 3/4 inch minimum
Strike plate
18 gauge metal, four offset screw holes
Strike plate screws
3 inch screws, 1 inch into the stud
Steel door thickness
24-gauge minimum
Wood door thickness
Solid core, 1-3/4 inches minimum
Entry door viewer
Field of view of at least 180 degrees
Code section
Lenexa City Code 4-8-A-19

Summary

In the City of Lenexa, Kansas, Section 4-8-A-19 adds physical security rules for dwelling units. Exterior doors need a single cylinder deadbolt with a one inch projection that penetrates at least three-fourths inch, and strike plates must be 18 gauge metal fastened with three inch screws.

1010.4.4 Door hardware. Exterior door hardware shall comply with Sections 1010.4.4.1 through 1010.4.4.5. ... 1010.4.4. ... 2 Strike plates. Exterior door strike plates shall be a minimum of 18 gauge metal with four offset screw holes. Strike plates shall be attached to wood with not less than three inch (3") screws, which shall have a minimum of one inch (1") penetration into the nearest stud. ... 1010.4.4.3 Locks. Exterior doors shall be provided with a locking device complying with all of the following: Single Cylinder Deadbolt shall have a minimum projection of one inch (1"). The deadbolt shall penetrate at least three-fourths inch (3/4") The cylinder shall have a twist-resistant, tapered hardened stell cylinder guard. Bolt assembly (Bolt housing) unit shall be of single piece construction.

Full Breakdown

The City of Lenexa, Kansas, adds Section 1010.4 to the International Building Code through Section 4-8-A-19. Its stated purpose is to set minimum standards that incorporate physical security so dwelling units resist unlawful entry, and it applies to all new structures and to alterations, additions and repairs as stipulated in the International Existing Building Code. The rules reach every swinging door that gives access into a dwelling unit of a residential building or an attached garage, including the door from the garage into the dwelling, but not vehicular access doors.

The hardware standard is in 1010.4.4. Locks must include a single cylinder deadbolt with a minimum projection of one inch that penetrates at least three-fourths inch, a twist-resistant, tapered hardened steel cylinder guard, and a bolt housing of single piece construction. Strike plates must be at least 18 gauge metal with four offset screw holes, attached to wood with screws of not less than three inches that penetrate at least one inch into the nearest stud. Hinges on exterior swinging doors take at least two 3 inch screws penetrating at least one inch into the wall structure, and out-swinging doors need a mechanical interlock so the door cannot be removed from outside. Main entry doors must let the occupant see outside without opening the door, through a viewer with a field of view of at least 180 degrees or through windows or view ports.

The door itself is regulated too. Exterior wood doors must be solid core at least 1-3/4 inches thick, steel doors at least 24-gauge, and fiberglass doors need a skin of at least one-sixteenth inch with reinforcement at the deadbolt. The inactive leaf of double doors needs flush bolts with at least one inch of engagement, and sliding glass doors need a secondary locking device, either a metal pin or a surface mounted bolt. Door frames must be installed before the rough-in inspection. The enforcing authority can approve an alternate material or method that is at least equivalent in burglary resistance and safety (1010.4.7).

Violations & Fines

Section 4-8-A-9 makes it unlawful to build or alter a structure in conflict with the permit, approved plans or any Chapter 4-8 provision. Penalties come from Section 1-1-C-3: a fine of not more than $2,500, imprisonment for not more than one year, or both, and each day is a separate offense. In practice the Building Official can withhold approval at inspection until the door hardware meets Section 4-8-A-19.

Frequently Asked Questions

What deadbolt does Lenexa require on exterior doors?
Section 4-8-A-19 (1010.4.4.3) requires a single cylinder deadbolt with a minimum projection of one inch that penetrates at least three-fourths inch. The cylinder needs a twist-resistant, tapered hardened steel cylinder guard, and the bolt housing must be a single piece. These standards apply to exterior doors into dwelling units and attached garages.
What are Lenexa's strike plate requirements?
Exterior door strike plates must be a minimum of 18 gauge metal with four offset screw holes. When attached to wood, the screws must be not less than three inches long and penetrate at least one inch into the nearest stud. Side lighted units follow the separate side light framing rules in 1010.4.4.5.
Do the Lenexa door security rules apply to my existing house?
Section 1010.4.1.1 applies the rules to all new structures and to alterations, additions and repairs as stipulated in the International Existing Building Code. The text does not require retrofitting an untouched existing home, so the rules matter when you build new or permit work that alters a covered door.
Does Lenexa require a peephole or door viewer?
Yes, for the main or front entry door of a dwelling unit. Section 1010.4.4.4 requires the door to be arranged so the occupant can see the area immediately outside without opening it. A door viewer with a field of view of not less than 180 degrees, windows or view ports satisfy the rule.

Sources & Official References

Other rules in Lenexa

All Lenexa rules

Compare Lenexa to another location·View the Kansas building safety overview

Get notified when Door Locking Hardware in Lenexa, KS changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Door Locking Hardware in Nearby Cities

How other cities in Johnson County handle door locking hardware.

Olathe, KS
Some Restrictions