Fire Sprinkler Requirements

In the City of Yucaipa, an accessory dwelling unit has to provide fire sprinklers only if sprinklers are required for the Primary Dwelling Unit on the same lot. The Development Code ties the ADU to the main house and also requires the ADU to comply with the California Building Standards Code, as amended by the City.

Fire Sprinkler Rule for Yucaipa Accessory Dwelling Units

Light Restrictions

Yucaipa Development Code § 84.0570(b), (c)(11), (c)(12)

"Primary Dwelling Unit" means the existing or proposed single-family residence that is located on the lot where the accessory dwelling unit will be constructed or converted. ... (11) Fire sprinklers. ADUs are required to provide fire sprinklers only if they are required for the Primary Dwelling Unit. (12) Building standards. ADUs shall comply with the California Building Standards Code, as amen...

Door Locking Hardware

In the City of Yucaipa, California, every door giving ingress and egress to a dwelling unit under the Multiple Residential Design Standards needs a wide-angle peephole and a deadbolt lock attached to the construction studding. Yucaipa Development Code § 88.0210(g) says attachment to the doorjamb or trim is not enough.

Peephole and Deadbolt Rules for Yucaipa Apartments

Some Restrictions

Yucaipa Development Code § 88.0210

(g) Each door providing ingress and egress to any dwelling unit subject to this ordinance shall be equipped with the following devices: (1) A peephole allowing a person inside the unit to see, at a wide angle, persons outside of the unit at the door, without the person inside being seen. The Planning Commission and/or City Council may consider other options to a peephole which provide like secu...

Green Building Code

In the City of Yucaipa, California, the California Green Building Standards Code, 2025 Edition (Part 11, Title 24), is adopted as the city's Green Building Standards Code by Yucaipa Municipal Code § 15.04.116. A separate city chapter makes CALGreen recycling space and construction waste rules a condition of permit approval for multifamily projects of five or more units and larger commercial projects.

Yucaipa CA Green Building Standards Code (CALGreen) Rules

Some Restrictions

Yucaipa Municipal Code § 15.04.116

Except as hereinafter provided, the California Green Building Standards Code, 2025 Edition (Part 11, Title 24, California Code of Regulations), published by the California Building Standards Commission, is hereby made a part hereof as though set forth at length and the same shall be established and adopted as the rules, regulations, provisions and conditions for the construction, enlargement, a...

Electrical Permits

In the City of Yucaipa, California, electrical work is governed by the California Electrical Code, 2025 Edition, which amends the 2023 National Electrical Code and is adopted by Yucaipa Municipal Code § 15.04.030 together with permit issuance and fee collection. Local amendments require copper wire for No. 6 and smaller, require continuous inspection of aluminum branch-circuit conductors, and place the PV disconnect within 3 feet of the main meter.

Yucaipa CA Electrical Permit and Electrical Code Rules

Some Restrictions

Yucaipa Municipal Code § 15.04.030

Except as hereinafter provided, the California Electrical Code, 2025 Edition (Part 3, Title 24, California Code of Regulations), including all annexes, which incorporates and amends the National Electrical Code, 2023 Edition, published by the National Fire Protection Association, is hereby adopted by reference as the electrical code of the City of Yucaipa for regulating the design, construction...

Plumbing Permits

In the City of Yucaipa, California, plumbing work is governed by the California Plumbing Code, 2025 Edition, which amends the 2024 Uniform Plumbing Code and is adopted by Yucaipa Municipal Code § 15.04.035 together with permit issuance and fee collection. Local amendments require backwater valves on low fixtures and prohibit both backwater valves and cleanouts on garage floors.

Yucaipa CA Plumbing Permit and Plumbing Code Rules

Some Restrictions

Yucaipa Municipal Code § 15.04.035

Except as hereinafter provided, the California Plumbing Code, 2025 Edition (Part 5, Title 24, California Code of Regulations), including all appendices, which incorporates and amends the Uniform Plumbing Code, 2024 Edition, published by the International Association of Plumbing and Mechanical Officials, including Uniform Plumbing Code Appendices thereto, not in conflict with the California Plum...

Building Inspections

In the City of Yucaipa, California, a re-inspection fee can be imposed when work called for inspection is not complete, required corrections are not made, plans or the inspection record card are missing from the site, or access is not provided. The first rejection for a code failure carries no re-inspection fee. Yucaipa Municipal Code § 15.04.015 adds this as Section 109.8 and stops further inspections until assessed fees are paid.

Yucaipa CA Building Inspection and Re-inspection Rules

Some Restrictions

Yucaipa Municipal Code § 15.04.015

109.8 Re-inspection Fees. A re-inspection fee may be imposed for each inspection or reinspection, when such portion of work for which inspection is called is not complete or when required corrections are not made. This section is not to be interpreted as requiring re-inspection fees the first time a job is rejected for failure to comply with the requirements of the technical codes, but as a met...