Eagle Mountain, UT Data Centers & Crypto Mining: Data Center Zoning & Siting (2026)
Key Facts
- Base zoning
- Permitted (P), EMMC 17.40.020 Industrial zone
- Special use conditions
- None; not marked 'S' in table
- Max height
- 5 stories, EMMC 17.40.050
- Setbacks
- 25 ft front, 50 ft sides, 20-50 ft rear
- Large-project overlay
- RTI Ch. 17.48, 100 jobs/100,000 sq ft trigger
Summary
Eagle Mountain treats data centers as a standard permitted use in its industrial zone, with no special approval required. EMMC 17.40.020's land use table marks 'Data Center' 'P' among the industrial zone's mixed industrial uses, alongside flex-space, light manufacturing, and office parks; a data center just needs the site plan review the industrial zone already requires.
P = Permitted. ... Industrial Land Uses Land Use(s) Ind. ... Data Center P
Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance O-34-2026, passed August 4, 2026).
Full Breakdown
Under EMMC 17.40.020, the industrial zone's land use table lists 'Data Center' with a straight 'P,' the same permitted-use mark given to flex-space structures, light manufacturing of finished products, industrial parks, and office parks in that zone; unlike uses such as automobile sales/service or heavy/large product manufacturing, which the table marks 'S' for special use requiring the standards in Chapter 17.75 EMMC, a data center carries no additional special-use conditions. Development still runs through the ordinary industrial-zone process: EMMC 17.40.030 requires a master site plan for any development in the district, and EMMC 17.40.040 sets base setbacks of 25 feet front, 50 feet on sides (with no side setback required between adjoining industrial lots), and 20 feet at the rear, rising to 50 feet where the rear yard adjoins a residential zone or faces an arterial or collector street; EMMC 17.40.050 caps building height at five stories.
A larger data center project can instead route through the regional technology and industry (RTI) overlay zone, Chapter 17.48 EMMC, whose land use table separately permits 'electronic data management businesses.' EMMC 17.48.020 requires the special RTI approval process, including a city council-approved development agreement and Development Review Committee (DRC) site plan review, for any project with a minimum of 100 or more permanent jobs at an average hourly wage equal to or greater than Utah County's average hourly wage, or a minimum of 100,000 square feet of building floor area in a building or buildings within a single phase of development. RTI site plans and final plats are administrative applications, and the DRC has final approval authority with no public hearings required under EMMC 17.48.020(E).
Violations & Fines
A data center that departs from the industrial zone's setback, height, or site plan requirements in EMMC 17.40.030 through 17.40.050 is a Title 17 development-standards violation the planning director investigates under EMMC 17.15.020(E), which can require the project to be brought into compliance before occupancy. A project that meets the RTI overlay's 100-job or 100,000-square-foot thresholds but proceeds without the EMMC 17.48.020 development agreement and DRC site plan approval has skipped a mandatory step in that special approval process.
Frequently Asked Questions
Does a data center need a special use permit in Eagle Mountain?
What building height applies to a data center in the industrial zone?
When does a data center have to go through the RTI overlay's special approval process?
Sources & Official References
Other rules in Eagle Mountain
Compare Eagle Mountain to another location·View the Utah data centers & crypto mining overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Data Center Zoning & Siting in Nearby Cities
How other cities in Utah County handle data center zoning & siting.