Bulloch County, GA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard requirement
- Lowest floor 2 ft above base flood elevation
- Utility elevation
- HVAC/electrical/plumbing 1 ft above base flood elevation
- Flood-proofing alternative
- Non-residential only, watertight to +2 ft
- No-data areas
- Lowest floor 3 ft above highest adjacent grade
- Certification required from
- Registered professional engineer or architect
- Local administrator
- Building official
Summary
New construction and substantial improvements in a Bulloch County special flood hazard area must have the lowest floor elevated at least two feet above the base flood elevation under § 7-37(1), with HVAC, electrical, and plumbing equipment raised at least one foot above that same elevation. Non-residential buildings may be flood-proofed instead.
(1)New construction and/or substantial improvements. Where base flood elevation data are available, new construction and/or substantial improvement of any structure or manufactured home shall have the lowest floor, including basement, elevated no lower than two feet above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate equalization of flood hydrostatic forces on both sides of exterior walls shall be provided in accordance with standards of section 7-36(9), "elevated buildings."a.All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities shall be elevated at or above one foot above the base flood elevation.
Full Breakdown
Bulloch County Code § 7-37(1) sets the county's freeboard standard: where base flood elevation data are available, new construction and substantial improvements to any structure or manufactured home must have the lowest floor, including any basement, elevated no lower than two feet above the base flood elevation, two feet more protection than the federal minimum. If solid perimeter walls are used to elevate the structure, the walls need flood-vent openings meeting § 7-36(9), which requires at least one square inch of opening per square foot of enclosed area, with the lowest opening no higher than one foot above grade.
Heating and air conditioning equipment, ductwork, electrical, ventilation, and plumbing service facilities must be elevated to at least one foot above the base flood elevation as well. Section 7-37(2) lets non-residential structures in A or AE zones be flood-proofed instead of elevated, so long as the structure and its utilities are watertight to two feet above base flood elevation, with walls able to resist hydrostatic and hydrodynamic loads, and a registered professional engineer or architect certifies the design. Where no base flood elevation data exist, § 7-39 instead requires the lowest floor to sit at least three feet above the highest adjacent grade at the building site, and keeps fill and structures at least 20 feet, or the width of the stream, back from the top of the bank.
Violations & Fines
Building below the required elevation, or occupying a flood-proofed non-residential structure without the engineer's certification required by § 7-37(2), is a violation of Chapter 7 enforced under § 7-12, punishable under the county's general penalty section, with each day of noncompliance treated as a separate offense. The building official records and certifies the as-built lowest-floor elevation for every project, and incomplete or missing certification data must be corrected before further construction may proceed.
Frequently Asked Questions
How far above base flood elevation must a new home be built in Bulloch County?
Can a commercial building in Bulloch County be flood-proofed instead of elevated?
What if there's no base flood elevation data for my Bulloch County lot?
Sources & Official References
Other rules in Bulloch County
Compare Bulloch County to another location·View the Georgia environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.