Coeur d'Alene, ID Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Flood protection elevation
- BFE plus floodway elevation, if present, plus zero freeboard
- Base flood
- One percent (1%) chance annual flood
- Residential lowest floor
- At or above the flood protection elevation
- Enclosure openings
- Minimum two openings, one square inch per square foot enclosed
- Nonresidential floodproofing
- Watertight to FPE or one foot above BFE, whichever is higher
- Crawl space limits
- Height not over four feet; grade not over two feet below LAG
Summary
In the City of Coeur d'Alene the flood protection elevation equals the base flood elevation plus the floodway elevation, if present, plus zero freeboard. New residential construction and substantial improvements with base flood elevation data must put the lowest floor, including basement, at or above that elevation.
FLOOD PROTECTION ELEVATION (FPE): An elevation that corresponds to the elevation of the one percent (1%) chance annual flood (100-year flood) plus any increase in elevation due to floodway encroachment, plus any required freeboard. The city does not allow an increase in water surface elevation in the floodway and no additional freeboard is required. Therefore the flood protection elevation is equal to the base flood elevation plus the floodway elevation, if present, plus zero freeboard. ... Where base flood elevation data are available, new construction or substantial improvement of any residential structure or manufactured home must have the lowest floor, including basement, constructed at or above the flood protection elevation. All new construction or substantial improvements of an existing residential structure that includes a fully enclosed area located below the lowest floor formed by the foundation and other exterior walls must be designed to be an unfinished or flood resistant enclosure.
Full Breakdown
Chapter 15.32 sets the elevation rule through a definition and a construction standard. The definition of flood protection elevation (FPE) in Section 15.32.040 starts from the one percent (1%) chance annual flood, the 100-year flood, adds any increase due to floodway encroachment and any required freeboard, and then states the city position: the city does not allow an increase in water surface elevation in the floodway and no additional freeboard is required. The FPE is the base flood elevation plus the floodway elevation, if present, plus zero freeboard. The base flood elevation (BFE) is the water surface elevation during the base flood, depicted on the FIRM to the nearest foot and in the FIS to the nearest 0.10 foot, measured against the NAVD88 vertical datum. The code still defines freeboard as a factor of safety in feet above a flood level, meant to cover wave action, obstructed bridge openings, debris and ice jams and the hydrologic effects of urbanization.
Section 15.32.130 applies the FPE to homes. Where BFE data are available, the lowest floor of new residential construction or substantial improvement, including basement, must be at or above the FPE. A fully enclosed area below the lowest floor must be an unfinished or flood resistant enclosure with a minimum of two (2) openings, a total net area of not less than one square inch for every square foot of enclosed area, and the bottom of every opening no higher than one foot (1') above the higher of the exterior or interior grade. The enclosure can only be used for parking of vehicles, limited storage of maintenance equipment or entry to the elevated area, and cannot be partitioned or finished into separate rooms. Below grade crawl spaces are prohibited where floodwater velocity exceeds five feet (5') per second, the interior grade cannot be more than two feet (2') below the lowest adjacent exterior grade, and the crawl space height cannot exceed four feet (4').
Nonresidential buildings in zones A1-30, AE or AH not elevated to the FPE must be floodproofed watertight to the FPE or to one foot (1') above the BFE, whichever is higher, under Section 15.32.140, with a licensed professional engineer or architect certifying the design to the administrator. Section 15.08.005 deletes IRC Section R322 so this chapter governs flood-resistant construction.
Violations & Fines
Section 15.32.220 bars locating, extending, converting or altering any structure or land unless in full compliance with the chapter. A violation, including breaking conditions attached to a variance or special exception, is a misdemeanor punishable under chapter 1.28. Section 1.28.010 sets a fine of not more than $1,000, imprisonment not to exceed 180 days, or both, with each day a separate offense. The city may also take other lawful actions to prevent or remedy a violation.
Frequently Asked Questions
Does Coeur d'Alene require freeboard above the base flood elevation?
How high must the lowest floor of a new home be?
What are the crawl space limits in a flood area?
What does the City mean by base flood elevation?
Sources & Official References
Other rules in Coeur d'Alene
Compare Coeur d'Alene to another location·View the Idaho environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.