Farmersville, TX Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard
- lowest floor 2 feet above base flood elevation (§26-80(1))
- Certification
- required from licensed engineer/architect/surveyor (§26-51(a)(3))
- Enclosure vents
- 1 sq in per sq ft, openings ≤1 ft above grade (§26-80(3))
- Manufactured homes
- same 2-ft elevation in Zones A1-30/AH/AE (§26-80(4)(b))
- Fine
- up to $2,000 per violation per day (§26-78)
Summary
New homes and substantial improvements built in Farmersville's mapped flood hazard areas must have their lowest floor, including any basement, elevated at least two feet above the base flood elevation set on FEMA's flood insurance rate maps. A licensed engineer, architect or land surveyor must certify compliance to the city's floodplain administrator before approval.
(1)Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated to two feet above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in section 26-51(a) is satisfied.
Full Breakdown
Section 26-80 sets Farmersville's specific floodplain construction standards wherever base flood elevation data exists under section 26-25. New construction and substantial improvement of a residential structure must have the lowest floor, including any basement, elevated to two feet above the base flood elevation, certified to the floodplain administrator by a registered professional engineer, architect or land surveyor under section 26-51(a)(3). Nonresidential buildings get an alternative: elevate the lowest floor the same two feet above base flood elevation, or floodproof the structure below that level so walls and utilities are substantially watertight and can resist hydrostatic and hydrodynamic loads, certified by a registered engineer or architect and recorded by the floodplain administrator.
Fully enclosed areas below the lowest floor used only for parking, building access, or storage must be designed to automatically equalize floodwater pressure, meeting a minimum of two openings on separate walls totaling at least one square inch of net area per square foot of enclosed space, with the bottom of each opening no higher than one foot above grade. Manufactured homes placed in Zones A1-30, AH, or AE outside an existing park must sit on a permanent foundation elevated so the lowest floor is also two feet above base flood elevation, anchored to resist flotation, collapse, and lateral movement. Violating any of these construction standards is a misdemeanor under section 26-78, fined up to $2,000 per violation with each day counted separately.
Violations & Fines
Constructing or substantially improving a structure below the required two-foot freeboard, or without the engineer's elevation certification required by section 26-51(a)(3), is a misdemeanor under section 26-78: a fine up to $2,000 for each violation, plus costs, with every day of noncompliance a separate offense. The floodplain administrator can also deny the development permit outright.
Frequently Asked Questions
How high above base flood elevation must a new Farmersville home sit?
Can a commercial building in the floodplain skip the elevation requirement?
What if my manufactured home sits in a Farmersville flood zone?
Sources & Official References
Other rules in Farmersville
Texas rules heatmap·Compare Farmersville to another location·View the Texas environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation Requirements in Nearby Cities
How other cities in Collin County handle flood elevation requirements.