Key Facts

Freeboard
lowest floor 2 feet above base flood elevation (§26-80(1))
Certification
required from licensed engineer/architect/surveyor (§26-51(a)(3))
Enclosure vents
1 sq in per sq ft, openings ≤1 ft above grade (§26-80(3))
Manufactured homes
same 2-ft elevation in Zones A1-30/AH/AE (§26-80(4)(b))
Fine
up to $2,000 per violation per day (§26-78)

Summary

New homes and substantial improvements built in Farmersville's mapped flood hazard areas must have their lowest floor, including any basement, elevated at least two feet above the base flood elevation set on FEMA's flood insurance rate maps. A licensed engineer, architect or land surveyor must certify compliance to the city's floodplain administrator before approval.

(1)Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated to two feet above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in section 26-51(a) is satisfied.

Full Breakdown

Section 26-80 sets Farmersville's specific floodplain construction standards wherever base flood elevation data exists under section 26-25. New construction and substantial improvement of a residential structure must have the lowest floor, including any basement, elevated to two feet above the base flood elevation, certified to the floodplain administrator by a registered professional engineer, architect or land surveyor under section 26-51(a)(3). Nonresidential buildings get an alternative: elevate the lowest floor the same two feet above base flood elevation, or floodproof the structure below that level so walls and utilities are substantially watertight and can resist hydrostatic and hydrodynamic loads, certified by a registered engineer or architect and recorded by the floodplain administrator.

Fully enclosed areas below the lowest floor used only for parking, building access, or storage must be designed to automatically equalize floodwater pressure, meeting a minimum of two openings on separate walls totaling at least one square inch of net area per square foot of enclosed space, with the bottom of each opening no higher than one foot above grade. Manufactured homes placed in Zones A1-30, AH, or AE outside an existing park must sit on a permanent foundation elevated so the lowest floor is also two feet above base flood elevation, anchored to resist flotation, collapse, and lateral movement. Violating any of these construction standards is a misdemeanor under section 26-78, fined up to $2,000 per violation with each day counted separately.

Violations & Fines

Constructing or substantially improving a structure below the required two-foot freeboard, or without the engineer's elevation certification required by section 26-51(a)(3), is a misdemeanor under section 26-78: a fine up to $2,000 for each violation, plus costs, with every day of noncompliance a separate offense. The floodplain administrator can also deny the development permit outright.

Frequently Asked Questions

How high above base flood elevation must a new Farmersville home sit?
Two feet. Section 26-80(1) requires the lowest floor, including any basement, of new construction or a substantial improvement to a residential structure to be elevated at least two feet above the base flood elevation shown on FEMA's maps, certified by a registered engineer, architect, or land surveyor.
Can a commercial building in the floodplain skip the elevation requirement?
Only by floodproofing instead. Section 26-80(2) lets nonresidential structures either elevate the lowest floor two feet above base flood elevation or floodproof everything below that level so walls and utilities resist floodwater, certified by a registered engineer or architect and recorded with the floodplain administrator.
What if my manufactured home sits in a Farmersville flood zone?
Section 26-80(4)(b) requires manufactured homes placed or substantially improved in Zones A1-30, AH, or AE outside an existing park to sit on a permanent foundation with the lowest floor elevated two feet above base flood elevation and anchored against flotation, collapse, and lateral movement.

Sources & Official References

Other rules in Farmersville

All Farmersville rules

Texas rules heatmap·Compare Farmersville to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Farmersville, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Collin County handle flood elevation requirements.

McKinney, TX
Some Restrictions
Allen, TX
Some Restrictions
Frisco, TX
Some Restrictions
Plano, TX
Significant Restrictions