Georgetown, KY Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified November 2026

Key Facts

Residential freeboard
Lowest floor no lower than two feet above base flood elevation
AO zone
FIRM depth number above highest adjacent grade, or two feet if none
Non-residential option
Floodproof to two feet above base flood elevation
Flood openings
Two openings, one square inch per square foot of enclosed area
Elevation certification
Registered professional engineer or surveyor, verified by building inspection
Manufactured home piers
Chassis on reinforced piers at least 36 inches above grade

Summary

Georgetown requires the lowest floor of new and substantially improved residential structures in special flood hazard areas to sit no lower than two feet above the base flood elevation, basement, mechanical equipment and ductwork included. Non-residential buildings must match that elevation or be floodproofed to two feet above it, under Georgetown Code § 18-87.

(1) Residential construction. New construction and substantial improvement of any residential structure (including manufactured home) shall have the lowest floor, including basement, mechanical equipment, and ductwork elevated no lower than two feet above the base flood elevation. ... a. In an AO zone, the lowest floor shall be elevated above the highest adjacent grade to a height equal to or higher than the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified. ... c. In all other zones, elevated two feet above the base flood elevation. Upon the completion of the structure, the elevation of the lowest floor (including basement) shall be certified by a registered professional engineer or surveyor, and verified by the community building inspection department to be properly elevated. Such certification and verification shall be provided to the floodplain administrator.

View official code

Official source re-checked November 3, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 4).

Full Breakdown

Section 18-87 applies in every special flood hazard area where base flood elevation data have been provided under § 18-7. The Georgetown standard is a two-foot freeboard. New construction and substantial improvement of a residential structure, manufactured homes included, needs its lowest floor, including the basement, mechanical equipment and ductwork, elevated no lower than two feet above the base flood elevation.

The code then sorts by zone. In an AO zone the lowest floor goes above the highest adjacent grade to a height equal to or higher than the depth number in feet printed on the FIRM, or at least two feet above the highest adjacent grade if no depth number is specified. In an A zone where FEMA has produced no technical data, the floodplain administrator decides how the base flood elevation is determined, using detailed hydrologic and hydraulic analyses, existing data from other sources, approximate methods, historical data, or best supportable and reasonable judgment, and the lowest floor still goes no lower than two feet above that elevation. In all other zones the same two feet applies, and once the structure is complete a registered professional engineer or surveyor certifies the lowest floor elevation and the community building inspection department verifies it. Both the certification and the verification go to the floodplain administrator.

Non-residential buildings meet the same elevation or are floodproofed to two feet above the base flood elevation so the structure is watertight with walls substantially impermeable to water. Structural components must resist hydrostatic and hydrodynamic loads and the effects of buoyancy and debris, and a registered professional engineer or architect certifies the work and supplies design and operational maintenance plans to the floodplain administrator. Fully enclosed areas below the lowest floor that are used solely for parking, building access or storage must be built of flood resistant materials to two feet above the base flood elevation.

Flood openings need at least two openings with a total net area of not less than one square inch for every square foot of enclosed area, with the bottom of each no higher than one foot above foundation interior grade (§ 18-87(3)). In an existing manufactured home park, a home can instead sit on a chassis supported by reinforced piers at least 36 inches above the highest adjacent grade (§ 18-87(4)c). Other two-foot rules: critical facilities in the SFHA need the lowest floor elevated two feet or more above the base flood elevation (§ 18-92), and accessory structures in A zones need flood-resistant materials and utilities two feet above it (§ 18-91).

Violations & Fines

Chapter 18 violations are civil offenses enforced under Chapter 2, Article VI and classed as Class 3 violations (§ 18-13). Under § 2-842 an uncontested Class 3 citation carries an initial $200.00 fine plus $200.00 for each seven days unremedied, up to $1,000.00; a contested citation carries a maximum civil fine of $2,000.00. A building that falls short of the elevation standard also faces a stop-work order if the elevation survey is not submitted or its deficiencies are not corrected (§ 18-33(b)).

Frequently Asked Questions

How high above base flood elevation must a Georgetown home be built?
Section 18-87(1) requires the lowest floor of new construction and substantial improvement of a residential structure, including the basement, mechanical equipment and ductwork, to be elevated no lower than two feet above the base flood elevation. That applies in special flood hazard areas where base flood elevation data have been provided.
What if FEMA has not published a base flood elevation for my lot?
In an A zone with no FEMA technical data, § 18-87(1)b makes the floodplain administrator decide how the base flood elevation is determined. Methods listed include detailed hydrologic and hydraulic analyses, existing data from other sources, approximate methods, historical data and best supportable and reasonable judgment. The lowest floor then goes no lower than two feet above that elevation.
Can a commercial building floodproof instead of elevating?
Yes. Under § 18-87(2), a non-residential structure can be elevated to match the residential rule or floodproofed to an elevation two feet above the base flood elevation, watertight with walls substantially impermeable to water. A registered professional engineer or architect must certify it and provide design and operational maintenance plans to the floodplain administrator.
Who certifies the finished floor elevation?
For zones other than AO and unmapped A zones, § 18-87(1)c requires a registered professional engineer or surveyor to certify the elevation of the lowest floor, including the basement, once the structure is complete. The community building inspection department verifies it, and both go to the floodplain administrator.

Sources & Official References

Other rules in Georgetown

All Georgetown rules

Compare Georgetown to another location·View the Kentucky environmental rules overview

Get notified when Flood Elevation Requirements in Georgetown, KY changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.