Skip to main content
CityRuleLookup

Grand Prairie, TX Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Enforcing official
City Floodplain Administrator
Residential lowest-floor elevation
BFE +1 ft, or FIRM BFE +2 ft
Nonresidential floodproofing option
BFE plus two feet
Certification required
Registered engineer or surveyor
Permit required
Floodplain Development Permit before building
Fill setback
15 feet beyond structure limits
Penalty basis
Fined under Code § 1-8, per day

Summary

Any new home or business built in a mapped Grand Prairie floodplain must set its lowest floor at least one foot above the fully-developed base flood elevation, or two feet above FEMA's mapped 100-year BFE, whichever is higher, under UDC § 15.18.1. A registered Texas engineer or surveyor certifies the elevation to the City's Floodplain Administrator before the project closes out.

15.18.1 In all SFHAs where base flood elevations data has been provided as set forth in this Article, the following provisions are required: A. Residential Construction - New construction and substantial improvements of any residential structure shall have the lowest floor elevation (including basement) be the greater of one foot above the base flood elevation (BFE) for fully developed conditions in the watershed or two feet above the FEMA FIRM 100-year (1% annual chance) BFE that utilizes existing land use conditions. A registered surveyor or registered professional engineer shall submit a certification to the Floodplain Administrator that the standard of this subsection as proposed in Section 15.15.2 "Floodplain Development Permit (FDP) Procedures" of this Article has been followed.

Full Breakdown

Grand Prairie's Unified Development Code, Article 15, sets the flood-elevation standard for anything built in a Special Flood Hazard Area (SFHA) once base flood elevation (BFE) data exists. 1(A), new and substantially improved residential structures must have their lowest floor, including any basement, at the greater of one foot above the BFE calculated for a fully developed watershed, or two feet above the FEMA FIRM 100-year BFE based on current land use; parking areas and open storage only need one foot above the BFE. 2.

1(B), but may floodproof instead: the design must be sealed by a licensed Texas engineer, resist hydrostatic and hydrodynamic loads, and protect the structure to the BFE plus two feet, with a record of the certified elevation kept by the Administrator. Fill placed under a structure in the floodplain but outside the floodway must extend at least 15 feet beyond the building's limits, and any septic system must sit at the same lowest floor elevation as the structure. 1), with fees set by UDC Article 22. 1). 2). 1).

Violations & Fines

Building in a Special Flood Hazard Area without a Floodplain Development Permit is a violation under § 15.24.1(A); the violator must restore the property to its prior condition or complete the permitting process (§ 15.24.2). Conviction brings a fine under Code of Ordinances § 1-8, with each day of continued noncompliance a separate offense (§ 15.26.1). Sellers who skip the written floodplain disclosure before closing face the same penalty (§§ 15.12.1-15.12.2).

Frequently Asked Questions

How high above flood level must I build in Grand Prairie's floodplain?
Section 15.18.1(A) sets the lowest floor at the greater of one foot above the base flood elevation for a fully built-out watershed, or two feet above FEMA's mapped 100-year base flood elevation using current land use. Parking areas and open storage only need one foot of clearance above the BFE.
Who has to certify my home's flood elevation?
A Texas-registered surveyor or professional engineer must certify the elevation to the City's Floodplain Administrator, per the procedure in § 15.15.2, before the Floodplain Development Permit is closed out; the record is kept on file with the Administrator.
Can a commercial building floodproof instead of raising the floor?
Yes. Section 15.18.1(B)(4) lets nonresidential structures floodproof to the BFE plus two feet instead of elevating, but a licensed Texas engineer must seal the design and the work must meet FEMA's wet or dry floodproofing standards.
What happens if I build in the floodplain without a permit?
Section 15.24.1 makes it an offense to start development in a floodplain without a Floodplain Development Permit; you must restore the site to its original condition or go through the permit process, and you're fined under Code § 1-8 for each day the violation continues.

Sources & Official References

Other rules in Grand Prairie

All Grand Prairie rules

Texas rules heatmap·Compare Grand Prairie to another location·View the Texas environmental rules overview

Get notified when Flood Elevation Requirements in Grand Prairie, TX changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Dallas County handle flood elevation requirements.

Garland, TX
Some Restrictions
Mesquite, TX
Some Restrictions
Richardson, TX
Some Restrictions
Irving, TX
Significant Restrictions
Dallas, TX
Significant Restrictions
DeSoto, TX
Significant Restrictions