Gulfport, FL Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Accessory structure freeboard
- Base flood elevation plus 1 foot
- Exempt-building standard
- ASCE 24 flood-resistant construction
- FBC-covered buildings
- Florida Building Code flood provisions govern
- Accessory cap, Zone A/AE
- 600 square feet, one story
- Accessory cap, Zone V/VE
- 100 square feet maximum
Summary
Buildings exempt from the Florida Building Code in Gulfport's flood hazard areas must meet ASCE 24 flood-resistant construction. Accessory structures need flood-resistant materials and mechanical, electrical, and plumbing systems at least one foot above base flood elevation under Sec. 10.5-10.01.
(b)Design and construction of buildings, structures and facilities exempt from the Florida Building Code. Pursuant to section 10.5-4.03 of this chapter, buildings, structures, and facilities that are exempt from the Florida Building Code, including substantial improvement or repair of substantial damage of such buildings, structures and facilities, shall be designed and constructed in accordance with the flood load and flood resistant construction requirements of ASCE 24. ... (c)Non-elevated accessory structures. Accessory structures are permitted below elevations required by the Florida Building Code provided the accessory structures are used only for parking or storage and: ... (4)Have flood damage-resistant materials used below the base flood elevation plus one (1) foot.(5)Have mechanical, plumbing and electrical systems, including plumbing fixtures, elevated to or above the base flood elevation plus one (1) foot.
Full Breakdown
Sec. 01 of the floodplain management ordinance splits elevation duties between two standards. Buildings and structures the Florida Building Code covers, including substantial improvements or repairs of substantial damage, must meet the flood load and flood-resistant construction requirements of the Florida Building Code itself, per subsection (a). Buildings, structures, and facilities exempt from the Florida Building Code under Sec. 03, such as railroads, farm buildings, and temporary construction sheds, instead follow ASCE 24 under subsection (b). 2; in coastal high hazard Zone V/VE, they cannot sit below an elevated building and cannot exceed 100 square feet.
Every qualifying accessory structure must be anchored against flotation and lateral movement, built of flood damage-resistant materials below base flood elevation plus one foot, and have its mechanical, plumbing, and electrical systems, including fixtures, elevated to or above base flood elevation plus one foot. Sec. 02 defines freeboard as the added height above a flood level, such as base flood elevation, built in as a safety factor against unknown risks like wave action and urbanization effects. The design flood elevation used in these calculations follows the community's FEMA flood hazard map, with Zone AO defaulting to two feet of depth where the map lists no depth number.
Violations & Fines
Installing utilities, materials, or accessory structures below the required elevation, or without the certifications this chapter demands, is a violation under Sec. 10.5-8.01, and a building lacking lowest-floor elevation documentation is presumed noncompliant. The floodplain administrator can order corrections or refer the matter for enforcement under the general penalty, Sec. 1-6, up to a $500 fine or 60 days in jail, with each day of continuing violation a separate offense.
Frequently Asked Questions
How much freeboard does Gulfport require above base flood elevation?
What size accessory structure can stay below flood elevation in Gulfport?
What is freeboard under Gulfport's flood ordinance?
Sources & Official References
Other rules in Gulfport
Florida rules heatmap·Compare Gulfport to another location·View the Florida environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation Requirements in Nearby Cities
How other cities in Pinellas County handle flood elevation requirements.