Hammond, IN Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard added above BFE
- 2 feet (defines the FPG)
- Residential lowest floor, Zone A/AE/AH
- At or above FPG
- Residential lowest floor, Zone AO
- 2 feet above flood depth on FIRM
- Elevation datum used
- NAVD 88
- Flood opening minimum area
- 1 sq in per 1 sq ft of enclosed area
Summary
The City of Hammond, Indiana sets its flood protection grade (FPG) at the base flood elevation (BFE) plus 2 feet of freeboard under § 153.02, and § 153.42 requires new or substantially improved residential structures in Zone A or AE to elevate the lowest floor to or above that FPG.
BASE FLOOD ELEVATION (BFE). The water surface elevation of the base flood in relation to a specified datum, usually the North American Vertical Datum of 1988. ... FLOOD PROTECTION GRADE (FPG). The BFE plus 2 feet at any given location in the SFHA. ... FREEBOARD. ... A factor of safety, usually expressed in feet above the BFE, which is applied for the purposes of floodplain management. ... (2) In Zone A and Zone AE, new construction or substantial improvement of any residential structure shall have the lowest floor; including basement, at or above the FPG.
Full Breakdown
02's definitions establish the mechanics behind Hammond's elevation standard. BASE FLOOD ELEVATION (BFE) is defined as the water surface elevation of the base flood relative to a specified datum, usually the North American Vertical Datum of 1988. FLOOD PROTECTION GRADE (FPG) is then defined as the BFE plus 2 feet at any given location in the SFHA, with the same definition cross-referencing FREEBOARD, defined as a factor of safety, usually expressed in feet above the BFE, applied to compensate for unknown factors that could push flood heights above the calculated base flood.
For Zone AO sites, the BFE is instead equivalent to the flood depth on the FIRM measured from the highest adjacent grade, defaulting to 2 feet if no depth is specified. 42(B) applies that 2-foot freeboard standard operationally: in Zone A and Zone AE, new construction or substantial improvement of any residential structure must have its lowest floor, including any basement, at or above the FPG; in Zone AH the same lowest-floor-at-FPG standard applies, with drainage paths required around structures on slopes; in Zone AO the lowest floor must be elevated 2 feet above the flood depth shown on the FIRM (or 2 feet above the highest adjacent grade if no depth is specified).
42(B)(5) requires flood openings sized to at least 1 square inch of net area per square foot of enclosed area, on at least two different exterior walls, with the bottom of each opening no more than 1 foot above grade.
Violations & Fines
Section 153.99 makes noncompliance with the elevation and freeboard standards a violation of the floodplain chapter, treated as a common nuisance under the zoning ordinance and punishable by a fine of up to $1,000, with each day of continuing noncompliance a separate offense; a willful violation can also cause the property's flood insurance coverage to be suspended.
Frequently Asked Questions
How much freeboard does Hammond require above the base flood elevation?
How high must a new house's lowest floor be in a Hammond Zone AE area?
What if my Hammond lot is in Zone AO instead of Zone AE?
Are flood vents required if I elevate on solid foundation walls?
Sources & Official References
Other rules in Hammond
Compare Hammond to another location·View the Indiana environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.