La Grange, MO Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard
1 foot above base flood elevation
Applies to
New construction & substantial improvements
Non-residential option
Certified floodproofing in lieu of elevation
Certifier
Registered professional engineer or architect
Vent opening rule
1 sq in per sq ft, openings ≤1 ft above grade

Summary

New or substantially improved homes in La Grange's mapped flood zones must have the lowest floor, including the basement, built one foot above base flood elevation. Non-residential buildings get the same freeboard or an engineer-certified floodproofing alternative.

1. Residential construction. New construction or substantial improvement of any residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated to one (1) foot above base flood elevation. ... 2. Non-residential construction. New construction or substantial improvement of any commercial, industrial, or other non-residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated to one (1) foot above the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.

Full Breakdown

Section 405.040(B) of the La Grange City Code sets the specific elevation standard that applies once base flood elevation data exists for a site under Section 405.040(A)(2). Residential structures, including manufactured homes, must have the lowest floor elevated to one foot above base flood elevation, giving La Grange one foot of freeboard above the FEMA-mapped elevation. Non-residential buildings, such as commercial or industrial structures, may either meet that same one-foot freeboard standard or be floodproofed below the base flood elevation so the structure is watertight with walls substantially impermeable to water and components able to resist hydrostatic and hydrodynamic loads; a registered professional engineer or architect must certify that floodproofing standard and file the certification with the Floodplain Administrator under Section 405.030(C)(9).

Fully enclosed areas below the lowest floor used only for parking, building access or storage must have at least two openings with a combined net area of one square inch per square foot of enclosed area, with the bottom of each opening no higher than one foot above grade, so floodwaters can automatically enter and exit rather than build hydrostatic pressure on the walls. Manufactured homes get a parallel rule: the lowest floor must sit one foot above base flood elevation, or, in an existing manufactured home park not otherwise covered, the chassis may instead rest on reinforced piers at least thirty-six inches above grade.

Violations & Fines

Building or substantially improving a residential or non-residential structure below the required one-foot freeboard in a mapped flood zone violates Section 405.040 and is enforced through the code's general penalty provision, with each day of non-compliance treated as a separate offense; a structure without the required lowest-floor elevation certification is presumed in violation until documentation is provided.

Frequently Asked Questions

How high above the flood elevation must a La Grange home be built?
Section 405.040(B)(1) requires the lowest floor, including any basement, of new or substantially improved residential structures to be elevated to one foot above the base flood elevation shown for the site on the Lewis County Flood Insurance Rate Map.
Can a commercial building in La Grange be floodproofed instead of elevated?
Yes. Section 405.040(B)(2) lets non-residential structures either meet the same one-foot freeboard or be floodproofed watertight below that elevation, but a registered professional engineer or architect must certify the floodproofing meets the standard.
What is required for enclosed space below an elevated home's lowest floor?
Under Section 405.040(B)(3), enclosed areas below the lowest floor used for parking, access or storage need at least two openings totaling one square inch of net area per square foot enclosed, with each opening's bottom no higher than one foot above grade.

Sources & Official References

Other rules in La Grange

All La Grange rules

Compare La Grange to another location·View the Missouri environmental rules overview

Get notified when Flood Elevation Requirements in La Grange, MO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.