Lakewood, CA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Governing section
- Lakewood Municipal Code Sec. 8034.1.C
- AR Zone, no FIRM depth
- Elevate 2+ feet above adjacent grade
- AR Zone, with FIRM depth
- Elevate to that depth number
- AR Zone (post-certification)
- Lower of base flood elevation or 3 feet
- Manufactured homes
- Piers at least 36 inches above grade
- Certification
- Registered engineer or surveyor, verified by City inspector
Summary
New residential construction in Lakewood's AR flood hazard zone must have its lowest floor, including any basement, elevated above the highest adjacent grade, per Municipal Code Section 8034.1.C. The exact height depends on the FIRM map: the FEMA-listed depth number where one exists, at least two feet where none is specified, or the lower of the base flood elevation or three feet in the post-certification AR Zone.
C. Elevation and Floodproofing. (See definitions for "basement," "lowest floor," and "new construction.") 1. New residential construction, including manufactured homes, shall meet the standards of Section 8034 and shall have the lowest floor, including basement, elevated as follows: (a) In the AR (with base flood depth) zone, elevated above the highest adjacent grade to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified. (b) In the AR Zone, elevated using the lower of either the AR base flood elevation or the elevation that is 3 feet above the highest adjacent grade. (c) New manufactured homes shall be securely fastened to an adequately anchored foundation system to resist flotation, collapse and lateral movement ... Upon the completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by a City building inspector to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4901715; v5 updated 2026-04-28; through 04-28-2026).
Full Breakdown
C sets three elevation paths for new residential construction, including manufactured homes, in the special flood hazard area. In the AR Zone with a base flood depth listed on the Flood Insurance Rate Map, the lowest floor must be elevated above the highest adjacent grade to at least that depth number, or at least two feet above grade if no depth number is shown. In the AR Zone generally, the required elevation is the lower of the AR base flood elevation or three feet above the highest adjacent grade.
A new manufactured home must be securely fastened to an anchored foundation and either meet those same floor elevations or sit on reinforced piers at least thirty-six inches above grade. Once built, a registered professional engineer or surveyor must certify the lowest floor's elevation, and a City building inspector must verify it before the Floodplain Administrator will accept the project as compliant. 2: instead of elevating, it can be floodproofed below the required elevation so the structure is watertight, with a registered engineer or architect certifying the floodproofing meets the standard.
Enclosed areas below the lowest floor that are used only for parking, access, or storage need at least two openings totaling one square inch of net area per square foot of enclosed space, with the lowest opening no higher than one foot above grade, unless an engineer certifies an equivalent design, so floodwater can enter and exit without damaging the structure.
Violations & Fines
Building without meeting the required elevation or floodproofing standard leaves the structure noncompliant with a mandatory Municipal Code requirement, which Section 8032.2 makes a misdemeanor, and the required engineer's or surveyor's certification will not be available to satisfy the Floodplain Administrator's documentation requirement under Section 8033.2.D. Beyond the misdemeanor penalty, the City may take any lawful action needed to prevent or remedy the violation.
Frequently Asked Questions
How high must I elevate a new home's floor in Lakewood's AR flood zone?
Who certifies that my Lakewood flood-zone home is elevated correctly?
Can I floodproof a building instead of elevating it in Lakewood?
Sources & Official References
Other rules in Lakewood