Compton, CA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Enforcing official
Flood Plain Administrator
Elevation default
2 ft above highest adjacent grade
AR zone rule
Lower of AR BFE or 3 ft above grade
Certification required
Engineer/surveyor + City Building Inspector
Enclosure vents
1 sq in per sq ft, min 2 openings
Noncompliance
Misdemeanor

Summary

Compton requires new construction in mapped flood hazard areas to elevate the lowest floor above the flood depth shown on the federal flood map, or at least two feet above the highest adjacent grade if no depth is listed, under Municipal Code § 14-10.8. A Flood Plain Administrator reviews and certifies compliance before issuing a development permit.

New residential construction, including manufactured homes, shall meet the standards of subsection 14-10.8 and shall have the lowest floor, including basement, elevated as follows: (1) Elevated above the highest adjacent grade to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified. (2) Elevated using the lower of either the AR base flood elevation or the elevation that is three feet above the highest adjacent grade.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4952997; v15 updated 2026-07-14; through 07-14-2026).

Full Breakdown

Enacted by Ordinance No. 2000 for National Flood Insurance Program compliance, the flood plain regulations apply to all areas of special flood hazard designated on the FIRM. A development permit from the Flood Plain Administrator is required before any construction in these areas. New construction must be anchored against flotation, collapse, or lateral movement, built with flood-damage-resistant materials, and designed so electrical, heating, plumbing, and air conditioning equipment stay above flood levels. New residential construction, including manufactured homes, must have the lowest floor, including any basement, elevated to the flood depth number shown on the FIRM above the highest adjacent grade, or at least two feet above grade if no depth number is specified; in AR zones, builders use whichever is lower of the AR base flood elevation or three feet above the highest adjacent grade.

Manufactured and modular homes must be secured to an anchored foundation and either meet that same elevation or sit on reinforced piers at least 36 inches above grade. Once built, a registered professional engineer or surveyor must certify the lowest floor's elevation, and a City Building Inspector verifies it before the Flood Plain Administrator signs off. Non-residential buildings may instead be flood-proofed watertight below the required elevation if a registered engineer or architect certifies the walls and structural components can resist hydrostatic and hydrodynamic loads.

Enclosed areas below the lowest floor used only for parking, access, or storage must include flood-water equalization openings, either engineer-certified or at least two openings totaling one square inch of area per square foot of enclosed space, with opening bottoms no higher than one foot above grade.

Violations & Fines

A structure built without the required elevation certificate or other proof of compliance is presumed to be in violation under § 14-10.3's definition of 'Violation.' Section 14-10.4 states that violating these flood plain requirements, including conditions attached to a development permit, constitutes a misdemeanor, and the Flood Plain Administrator can also order remedial action to bring a noncompliant structure into line or reduce its flood-damage exposure.

Frequently Asked Questions

How high must I build in a Compton flood zone?
To the flood depth number shown on the federal flood map above the highest adjacent grade, or at least two feet above grade if the map lists no depth number, per Municipal Code § 14-10.8(a)(3). AR zones use whichever is lower of the AR base flood elevation or three feet above grade.
Who verifies the elevation is correct?
A registered professional engineer or surveyor must certify the finished lowest-floor elevation, and a City Building Inspector verifies it before the Flood Plain Administrator signs off, per Municipal Code § 14-10.8(a)(3)(b).
Can I skip elevating a commercial building?
Non-residential buildings may instead be flood-proofed watertight below the required elevation, provided a registered engineer or architect certifies the walls and structural components can resist flood loads, under Municipal Code § 14-10.8(b).
What if I build without the elevation certificate?
The code presumes that is a violation, and building without full compliance with the flood plain regulations is a misdemeanor under Municipal Code §§ 14-10.3 and 14-10.4.

Sources & Official References

Other rules in Compton

All Compton rules

California rules heatmap·Compare Compton to another location·View the California environmental rules overview

Get notified when Flood Elevation Requirements in Compton, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Los Angeles County handle flood elevation requirements.

West Covina, CA
Some Restrictions
Norwalk, CA
Some Restrictions
Carson, CA
Some Restrictions
South Gate, CA
Some Restrictions
Los Angeles, CA
Some Restrictions
Pasadena, CA
Some Restrictions
Palmdale, CA
Some Restrictions
Lakewood, CA
Some Restrictions