Skip to main content
CityRuleLookup

Medina, OH Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard required
2 feet above base flood elevation
Fallback standard
2 feet above highest adjacent natural grade
Applies to
New construction and substantial improvements, including manufactured homes
Enclosure vents
1 sq in per sq ft, openings within 1 foot of grade
Penalty class
Fourth-degree misdemeanor, strict liability

Summary

Medina requires two feet of freeboard above base flood elevation for any new or substantially improved residential structure. The Flood Protection Elevation defined in Section 1379.02(q) sets the lowest-floor target; where no base flood elevation data exists, the fallback is two feet above the highest adjacent natural grade under Section 1379.04(d)(5).

(q) Flood Protection Elevation: The Flood Protection Elevation, or FPE, is the base flood elevation plus two (2) feet of freeboard. In areas where no base flood elevations exist from any authoritative source, the flood protection elevation can be historical flood elevations, or base flood elevations determined and/or approved by the Floodplain Administrator. ... New construction and substantial improvement ... of any residential structure, including manufactured homes, shall have the lowest floor, including basement, elevated to or above the flood protection elevation (See Section 1379.02 "Definitions"). Where flood protection elevation data are not available the structure shall have the lowest floor, including basement, elevated at least two feet above the highest adjacent natural grade.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2025-01: Local legislation current through June 24, 2025 | State legislation current through December 31, 2024).

Full Breakdown

02(q); where no authoritative base flood elevation exists, the Floodplain Administrator may substitute historical flood elevations or an approved base flood elevation. 02(s) as the safety margin that compensates for unknowns such as wave action, obstructed bridge openings, debris and ice jams, and the effect of urbanization on runoff. 04(d)(5) turns that definition into a hard construction standard: new construction and substantial improvement of any residential structure, including manufactured homes, must have the lowest floor, including the basement, elevated to or above the Flood Protection Elevation.

If flood protection elevation data are not available for the site, the fallback is a minimum of two feet above the highest adjacent natural grade. Structures built on fill up to or above the base flood elevation are deemed to satisfy the related anchoring and flood-resistant-materials requirements. Enclosures below the elevated lowest floor are allowed only for parking, building access, or storage, and must either be engineered to automatically equalize hydrostatic forces or carry at least two flood vents per enclosed wall sized to one square inch per square foot of enclosed area, with openings no higher than one foot above grade.

Violations & Fines

Elevating a residential structure below the required Flood Protection Elevation, or filling in flood vents required under Section 1379.04(d)(6), is a violation of Chapter 1379 enforced under Section 1379.06. Violations are strict liability, fourth-degree misdemeanors prosecuted by the City, with each day of noncompliance a separate offense; the Floodplain Administrator can also require an Increased Cost of Compliance insurance claim process for substantially damaged structures rebuilt below standard.

Frequently Asked Questions

How high above base flood elevation must a new home's lowest floor sit in Medina?
At least two feet, called the Flood Protection Elevation under Section 1379.02(q). The lowest floor, including any basement, must be built to or above that elevation for all new construction and substantial improvements, including manufactured homes, per Section 1379.04(d)(5).
What if there's no published base flood elevation for my lot?
Section 1379.04(d)(5) supplies a fallback: elevate the lowest floor, including the basement, at least two feet above the highest adjacent natural grade. The Floodplain Administrator may also approve a substitute base flood elevation from historical flood data under Section 1379.02(q).
Can I finish a walkout basement below the Flood Protection Elevation?
Only if it functions purely as parking, building access, or storage and includes engineered flood vents. Section 1379.04(d)(6) requires either professional certification that the enclosure automatically equalizes hydrostatic pressure, or a minimum of two vents per wall sized at one square inch per square foot of enclosed area.

Sources & Official References

Other rules in Medina

All Medina rules

Compare Medina to another location·View the Ohio environmental rules overview

Get notified when Flood Elevation Requirements in Medina, OH changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.