Compiled from the official code textEditor Martyn O'NeillLast verified November 2026

Key Facts

Residential lowest floor
At least 3 feet above base flood elevation, basement included
Non-residential option
3 feet above base flood elevation, or floodproofed watertight below it
Elevation certification
Licensed land surveyor or professional engineer
AO zones
FIRM depth number above highest adjacent grade, 3 feet if none
Floodplain Administrator
City Manager of Paola
Maximum fine
$500.00 plus costs, each day a separate offense

Summary

In Paola's mapped flood zones where base flood elevation data have been provided, a new or substantially improved home must have its lowest floor, including the basement, at least three feet above base flood elevation. Non-residential buildings follow the same three-foot rule or can be floodproofed instead. A licensed land surveyor or professional engineer certifies the lowest-floor elevation.

1. In all areas identified as numbered and unnumbered A zones, AE, and AH Zones, where base flood elevation data have been provided, as set forth in Section 05.231 K(2), the following provisions are required: a. Residential Construction New construction or substantial-improvement of any residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated a minimum of three (3) feet above base flood elevation. The elevation of the lowest floor shall be certified by a licensed land surveyor or professional engineer. b. Non-Residential Construction New construction or substantial-improvement of any commercial, industrial, or other non-residential structures, including manufactured homes, shall have the lowest floor, including basement, elevated a minimum of three (3) feet above the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below the base flood elevation the structure is watertight

Full Breakdown

Section 05.231 N of Appendix C, the Land Development Ordinance, sets Paola's specific flood elevation standards. They apply in all areas identified as numbered and unnumbered A zones, AE and AH zones where base flood elevation data have been provided, as set forth in Section 05.231 K(2). The regulated area is tied to the Flood Insurance Rate Map and Flood Boundary and Floodway Map dated August 19, 2008 (Section 05.231 D), and in the defined flood areas no development is permitted without a floodplain development permit granted by the Governing Body.

Residential construction comes first. New construction or substantial improvement of a residential structure, manufactured homes included, must have its lowest floor, basement included, elevated a minimum of three (3) feet above base flood elevation. Non-residential structures carry the same three-foot figure, but the code adds a floodproofing alternative: the structure, together with its attendant utility and sanitary facilities, can instead be floodproofed so that it is watertight below the base flood elevation, with walls substantially impermeable to the passage of water. A registered professional engineer or architect must certify the floodproofing, and a licensed land surveyor or professional engineer must certify the elevation of the lowest floor.

The three-foot freeboard repeats elsewhere in the section. Manufactured homes in A, AE and AH zones must sit on a permanent foundation with the lowest floor at least three feet above the base flood elevation (Section 05.231 O). In AO zones, where shallow flooding runs one to three feet deep, the lowest floor must stand above the highest adjacent grade at least as high as the depth number on the FIRM, and at least three feet if no depth number is specified (Section 05.231 P). Fully enclosed areas below the lowest floor used solely for parking, building access or storage need a minimum of two openings, and the bottom of every opening can be no higher than one foot above grade. The City Manager is the designated Floodplain Administrator and keeps the record of the actual lowest-floor elevation of new or substantially improved structures (Section 20.350).

Violations & Fines

Violating the floodplain provisions, or failing to comply with any requirement including conditions attached to a variance, is a misdemeanor under Section 05.231 S. A conviction carries a fine of not more than $500.00 plus the costs and expenses of the case. Each day the violation continues is a separate offense, and the City of Paola can take other lawful action to prevent or remedy the violation.

Frequently Asked Questions

How high must a new house in a Paola flood zone be built?
Where base flood elevation data have been provided for the A, AE or AH zone, Section 05.231 N requires the lowest floor, including the basement, to be elevated a minimum of three feet above base flood elevation. Manufactured homes are covered by the same sentence, and a licensed land surveyor or professional engineer must certify the elevation.
Can a commercial building be floodproofed instead of elevated?
Yes. A commercial, industrial or other non-residential structure can either meet the three-foot elevation or, with its utility and sanitary facilities, be floodproofed so it is watertight below the base flood elevation. A registered professional engineer or architect must certify that the floodproofing standards are satisfied.
What happens in an unnumbered A zone with no base flood elevation?
Section 05.231 Q(4) directs the community to obtain, review and reasonably utilize any base flood elevation or floodway data currently available from Federal, State or other sources. The three-foot rule in Section 05.231 N is written for zones where base flood elevation data have been provided.
Who checks the elevation records in Paola?
The City Manager serves as Floodplain Administrator under Section 20.350. That office reviews floodplain development permit applications and must verify and maintain a record of the actual elevation of the lowest floor, including basement, of all new or substantially improved structures.

Sources & Official References

Other rules in Paola

All Paola rules

Compare Paola to another location·View the Kansas environmental rules overview

Get notified when Flood Elevation Requirements in Paola, KS changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.