Paola, KS Environmental Rules: Stormwater Management (2026)
Key Facts
- Storage volume
- 115 percent of excess flow from the 100-year, 24-hour storm
- Peak flow limit
- No higher than the natural, undeveloped condition
- Calculation standard
- APWA Division V, 5600 Storm Water Drainage System Manual
- Dry basin depth
- Four feet unless the Director of Public Works approves
- Monthly storm water charge
- $3.00 per utility account
- Enforcing officials
- Zoning Officer and Director of Public Works
Summary
Every new development in Paola must provide on- or off-lot detention for the extra stormwater it creates. Downstream owners cannot receive a higher peak flow than the land produced in its natural, undeveloped condition, and storage must hold 115 percent of the excess flow from the 100-year, 24-hour storm. Each utility account also pays a $3.00 monthly storm water charge.
A. Each development shall provide on- or off-lot detention of excess stormwater runoff resulting from that development. ... B. No development shall cause downstream property owners, water courses, channels, or conduits to receive stormwater runoff from proposed developments at a higher peak flow rate than would have resulted from the same storm event occurring over the proposed development site with the land in its natural, undeveloped condition. ... C. All stormwater storage facilities shall be designed with sufficient capacity to accommodate all runoff caused by the development in excess of the natural, undeveloped condition. The storage capacity of all storage facilities shall be sufficient to store one hundred fifteen (115) percent of the excess flow, in each watershed, which would result from the 100-year storm of 24-hour duration.
Full Breakdown
Section 12.120 of Paola's Land Development Ordinance (Appendix C, Article 12) is the operative stormwater rule for new projects. "Excess stormwater runoff" covers four things: added impervious surface from new buildings, roads and parking lots, soil compaction during development, contour changes such as filling depressions or altering drainageways, and altered subsurface flows. Detention is sized from the land use, pervious surface and impervious surface for nonresidential uses, while residential uses apply the residential size and lot type and count open space as pervious. Section 12.120(D) adopts the APWA Division V, 5600 Storm Water Drainage System Manual for calculating detention, and where the section conflicts with that manual the section controls.
Section 12.120(E) sets the design standards. Storage can be wet or dry bottom basins, reservoirs or rooftop storage, except in water supply watersheds, where every basin must be wet. A wet basin holds a water volume equal to at least a two (2) hour twenty (20) year storm, or a two (2) hour fifty (50) year storm in a water supply watershed. Outlet control structures operate automatically, emergency overflow is required, and a dry basin cannot hold more than four (4) feet of water unless the Director of Public Works approves. Paved parking lots can serve as temporary detention on no more than twenty-five (25) percent of their surface, and rooftop storage must be certified by a registered engineer and cannot drain directly into sanitary sewers or streets.
Section 12.110 asks for natural drainageways rather than an underground stormwater system, and open channel ditches can be no steeper than a 3:1 slope. After approval, the developer maintains the improvements until streets are accepted and a certificate of compliance is granted. Detention then stays with the owner, homeowners association or the City (if dedicated and accepted) in perpetuity. Separately, Chapter 15, Article 4 charges $3.00 per utility account per month, collected on the water, sewer and/or trash bill and held in a separate Storm Water Management Fund.
Violations & Fines
Section 12.120(A) through (G) prints no fine of its own. Enforcement runs through the Zoning Officer, who has "the explicit authority to compel compliance and require correction" when facilities are not built to approved plans, and through inspection by the Director of Public Works. For construction sites, Section 4-111(d) says missing or unmaintained BMPs mean a failed inspection, and future inspections are denied until they are installed or repaired.
Frequently Asked Questions
Does a new building in Paola have to manage its own stormwater?
How large does a detention facility have to be?
Can parking lots or roofs count as detention?
What is the Paola storm water charge?
Sources & Official References
Other rules in Paola
Compare Paola to another location·View the Kansas environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.