Parker, CO Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard required
2 feet above base flood elevation
Applies to
Residential, nonresidential, critical facilities
New buildings in 100-yr floodplain
Prohibited outright
RVs in flood hazard area
Prohibited
FIRM basis
FEMA Flood Insurance Study, Douglas County, 3/16/2016

Summary

In Parker's designated special flood hazard areas, new and substantially improved homes must have their lowest floor and mechanical equipment elevated at least two feet above the base flood elevation, and critical facilities need the same two-foot freeboard, under the Town's Floodplain Administrator.

1.Residential construction. ... Substantial improvement of any existing residential structure shall have the lowest floor (including basement), electrical, heating, ventilation, plumbing and air conditioning equipment elevated a minimum of two (2) feet above the base flood elevation. ... 3.Critical facilities. All new construction and substantial improvement of, and new additions to critical facilities shall have a minimum freeboard of two (2) feet above the base flood elevation.

Full Breakdown

Parker Municipal Code § 13.08.040(a)(6)b sets the Town's freeboard standard for flood hazard reduction, going beyond the minimum federal requirement by requiring a full two feet of elevation above the base flood elevation rather than matching it exactly. For residential construction, any substantial improvement to an existing home must have its lowest floor, including the basement, along with its electrical, heating, ventilation, plumbing, and air conditioning equipment, elevated at least two feet above the base flood elevation. Nonresidential structures face the same two-foot elevation requirement or, as an alternative, can be flood proofed so that everything below that two-foot mark is watertight with substantially impermeable walls, structural components able to resist hydrostatic and hydrodynamic loads, and certification from a registered professional engineer or architect.

Critical facilities, meaning things like emergency response buildings, must independently meet a minimum freeboard of two feet above base flood elevation under § 13.08.040(a)(6)b.3. New buildings and habitable structures are separately barred outright from any designated 100-year floodplain under § 13.08.040(a)(6)a.2, and recreational vehicles cannot be parked in the special flood hazard area at all. The areas of special flood hazard are drawn from FEMA's Flood Insurance Study for Douglas County, Colorado, dated March 16, 2016, and any floodplain development requires a Floodplain Development Permit reviewed under § 13.03.040(e) by the Town's Floodplain Administrator, who also handles the certification of engineering compliance required for flood-proofed alternatives.

Violations & Fines

Constructing or substantially improving a structure in the special flood hazard area without meeting the two-foot freeboard standard or without a Floodplain Development Permit violates the Land Development Ordinance under Parker Municipal Code § 13.01.080. The Town can fine the property owner up to $499 per violation, with each day of noncompliance a separate offense, and the Floodplain Administrator can withhold or revoke permit approval until the elevation requirements are met.

Frequently Asked Questions

How far above the base flood elevation must a home be built in Parker?
Parker Municipal Code § 13.08.040(a)(6)b.1 requires the lowest floor, including the basement, and all mechanical equipment of a substantially improved residence to be elevated at least two feet above the base flood elevation.
Do critical facilities have a different flood elevation standard in Parker?
They must meet the same two-foot standard as a minimum freeboard requirement under § 13.08.040(a)(6)b.3, applying to all new construction, substantial improvements, and additions to critical facilities.
Can nonresidential buildings in Parker's floodplain be flood-proofed instead of elevated?
Yes. Section 13.08.040(a)(6)b.2 allows flood-proofing to two feet above base flood elevation with watertight walls and engineer certification as an alternative to elevating the lowest floor.

Sources & Official References

Other rules in Parker

All Parker rules

Compare Parker to another location·View the Colorado environmental rules overview

Get notified when Flood Elevation Requirements in Parker, CO changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.