Parma, OH Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard requirement
Base flood elevation plus 2 feet
Default rule if no BFE data
2 feet above highest adjacent grade
Governing authority
Floodplain Administrator
Permit required
Floodplain development permit before construction
Penalty class
First-degree misdemeanor, strict liability
Enclosure vent rule
1 sq in per sq ft, 2+ openings

Summary

Parma requires new construction and substantially improved residential structures in special flood hazard areas to have the lowest floor, including the basement, elevated to or above the flood protection elevation: the base flood elevation plus two feet of freeboard. A floodplain development permit from the Floodplain Administrator is mandatory before any such work begins.

New construction and substantial improvement of any residential structure, including manufactured homes, shall have the lowest floor, including basement, elevated to or above the flood protection elevation. Where flood protection elevation data are not available, the structure shall have the lowest floor, including basement, elevated at least two feet above the highest adjacent natural grade.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 S-30: Local legislation current to August 3, 2026 | State legislation current to June 25, 2025).

Full Breakdown

03(r)). 25(d) applies that standard directly to residential construction: new construction and substantial improvement of any residential structure, including manufactured homes, must have the lowest floor, including basement, elevated to or above the flood protection elevation. Where flood protection elevation data are not available for a site, the lowest floor must instead be elevated at least two feet above the highest adjacent natural grade. 25(c) requires electrical, heating, plumbing and HVAC equipment to be elevated or otherwise protected from flood infiltration. 25(e) must either be engineered to automatically equalize hydrostatic forces or carry at least two flood openings on different walls totaling one square inch of net area per square foot of enclosed space, with opening bottoms no higher than one foot above grade.

26(b): the lowest floor must reach the flood protection elevation, or the building must be dry floodproofed watertight to that level and certified by a registered engineer or architect using a FEMA Floodproofing Certificate. 36(a) makes it a violation to build, alter, or enlarge any structure in the regulated area without first obtaining a floodplain development permit, and use or construction that departs from an approved permit is likewise a violation.

Violations & Fines

Failure to obtain a floodplain development permit, or building outside the terms of an issued permit, is a violation of Chapter 1526 under Section 1526.36(a)(2)-(3), triggering a written notice of violation from the Floodplain Administrator specifying required remedial action and a compliance deadline. Section 1526.99 makes any violation a strict liability offense and a first-degree misdemeanor, with each day of continuing violation charged as a separate offense; the city may pursue additional lawful remedies beyond prosecution.

Frequently Asked Questions

How high above the base flood elevation must a Parma home be built?
Section 1526.25(d) of the Codified Ordinances requires the lowest floor, including the basement, of new construction or a substantial improvement to sit at or above the flood protection elevation, which Section 1526.03(r) defines as the base flood elevation plus two feet of freeboard.
What if my lot has no base flood elevation data?
Section 1526.25(d) provides a fallback: where flood protection elevation data are unavailable, the lowest floor must still be elevated at least two feet above the highest adjacent natural grade on the site.
Can I finish the space below the elevated lowest floor?
Only for parking, building access, or storage under Section 1526.25(e). The enclosure must either be engineered to automatically equalize floodwater pressure or have at least two openings on different walls sized to one square inch per square foot of enclosed area.
What happens if I build without a floodplain permit?
Section 1526.36(a) makes construction without a floodplain development permit a violation, and Section 1526.99 classifies any violation as a strict liability first-degree misdemeanor, with each day of continued violation counted as a separate offense.

Sources & Official References

Other rules in Parma

All Parma rules

Compare Parma to another location·View the Ohio environmental rules overview

Get notified when Flood Elevation Requirements in Parma, OH changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Cuyahoga County handle flood elevation requirements.

Cleveland, OH
Some Restrictions