Skip to main content
CityRuleLookup

Pottstown, PA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard required
1 1/2 feet above base flood elevation
Applies to
new construction and substantial improvements
Governing standard
IBC, IRC, ASCE 24, 34 Pa. Code Ch. 401-405
Nonresidential alternative
dry-floodproofing to W1/W2 standards
A Zone method
Section 402D engineering determination

Summary

Pottstown requires new construction and substantial improvements in the floodplain to sit above the base flood elevation plus a mandatory 1.5-foot freeboard, defined in Chapter 8 as the 'regulatory flood elevation.' Section 702 applies that standard to lowest-floor elevation in AE and A Zones.

REGULATORY FLOOD ELEVATION The regulatory flood elevation is the elevation to which development is regulated for purposes of elevation and/or dry floodproofing. It is equal to the base flood elevation (BFE) plus a freeboard of 1 1/2 feet. ... § 702. Elevation and Floodproofing Requirements. ... 1. Residential Structures. A. In AE Zones, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 5012545; v22 updated 2026-07-13; through 07-13-2026).

Full Breakdown

Chapter 8, Part 3, Section 302 defines 'regulatory flood elevation' as the elevation to which development is regulated for elevation and dry floodproofing purposes, and fixes it as the base flood elevation (BFE) plus a freeboard of 1 1/2 feet, that is, one foot six inches of extra height above the FEMA-mapped one-percent-annual-chance flood level. Section 702, Elevation and Floodproofing Requirements, applies that standard directly: in AE Zones, any new construction or substantial improvement of a residential structure must have its lowest floor, including any basement, elevated up to or above the regulatory flood elevation, built to the specifications of the applicable International Building Code, International Residential Code, ASCE 24 and 34 Pa.

Code Chapters 401 through 405. In A Zones, where the FIRM does not print a base flood elevation, the same lowest-floor elevation is measured against a regulatory flood elevation the Borough determines under Section 402D using the nearest available floodplain boundary point or a licensed engineer's hydrologic and hydraulic study. 5-foot freeboard target, or may instead be dry-floodproofed watertight and built to resist hydrostatic and hydrodynamic loads under the Army Corps of Engineers' W1 or W2 space classification standards, certified by a registered engineer or architect.

The same freeboard figure recurs elsewhere in the chapter: Section 501G requires brownfield redevelopment structures in the floodplain to sit 1 1/2 feet above the flood elevation, and Section 504A requires any expansion or enlargement of an existing structure to be built at that same 1 1/2-foot elevation above base flood elevation.

Violations & Fines

A structure built without the elevation certificate or other compliance documentation required by federal flood insurance regulations is presumed to be in violation of the chapter until that documentation is produced. Noncompliant new construction or substantial improvement can be denied a floodplain permit outright, and the Borough may pursue code enforcement for construction that proceeds below the required regulatory flood elevation.

Frequently Asked Questions

How much higher than the base flood elevation must new construction be in Pottstown?
Section 302 defines the 'regulatory flood elevation' as the base flood elevation plus a freeboard of 1 1/2 feet, and Section 702 requires the lowest floor, including any basement, of new construction or substantial improvements to be built up to or above that regulatory flood elevation.
Does the freeboard rule apply outside FEMA's mapped AE Zone?
Yes. In A Zones, where the FIRM does not show a base flood elevation, Section 702 still requires the lowest floor elevated to the regulatory flood elevation, determined under Section 402D from the nearest floodplain boundary point or an engineering study.
Can a nonresidential building in Pottstown's floodplain skip elevating and floodproof instead?
Yes. Section 702 lets a nonresidential structure be built watertight and dry-floodproofed to the Army Corps of Engineers' W1 or W2 standards instead of elevating, but the design must be certified by a registered professional engineer or architect.
Does expanding an existing house in the Pottstown floodplain trigger the freeboard rule?
Yes. Section 504A requires any expansion or enlargement of an existing structure in the Floodplain Conservation District to be built at an elevation of 1 1/2 feet above the base flood elevation, the same freeboard applied to new construction.

Sources & Official References

Other rules in Pottstown

All Pottstown rules

Compare Pottstown to another location·View the Pennsylvania environmental rules overview

Get notified when Flood Elevation Requirements in Pottstown, PA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.