Sacramento, CA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified August 2026

Key Facts

Zones A, AH, AE freeboard
1 foot above base flood elevation
Magpie Creek standard
1 ft above 100-yr HGL + 18 in above release point
Zone AO
1 ft above depth number or 2 ft above grade
Utilities/mechanical equipment
Elevated/floodproofed 1 ft above BFE
Certification
Licensed civil engineer or land surveyor required

Summary

Sacramento requires new construction and substantial improvements in mapped flood zones to elevate the lowest floor at least one foot above the base flood elevation, with a stricter dual standard near Magpie Creek. Section 15.104.050(A)(3) sets zone-specific elevation rules, and a licensed engineer or surveyor must certify the finished elevation before the project is signed off.

Zone A. New construction and substantial improvement of any structure in zone A must have the lowest floor elevated a minimum of one foot above the base flood elevation. The applicant shall include base flood elevation data prepared and sealed by a California-licensed civil engineer in accordance with currently accepted engineering practices... Zones AH and AE. New construction and substantial improvement of any structure in zones AH and AE must have the lowest floor elevated a minimum of one foot above the base flood elevation specified in feet on the FIRM... Magpie Creek. New construction and substantial improvement of any structure in the Magpie Creek floodplain must have the lowest floor elevated a minimum of— (A) One foot above the highest adjacent 100-year flood HGL; and (B) 18 inches above the controlling overland release point in the public right-of-way.

Full Breakdown

050(A)(3)(a)(i) requires new construction and substantial improvements to have the lowest floor elevated at least one foot above the base flood elevation (BFE), with that BFE data prepared and sealed by a California-licensed civil engineer. In Zones AH and AE, the same one-foot freeboard applies but is measured against the BFE printed on the FIRM. Near Magpie Creek, the standard is doubled up: the lowest floor must sit at least one foot above the highest adjacent 100-year flood hydraulic grade line and at least 18 inches above the controlling overland release point in the public right-of-way.

In Zone AO, the lowest floor must be one foot above the FIRM's depth number at the highest adjacent grade, or two feet above the highest adjacent grade if no depth number is shown. Nonresidential structures may instead be dry-floodproofed to that same elevation with watertight walls and hydrostatic-load-resistant components, certified by a California-licensed civil engineer. 050(A)(3)(j). 050(A)(3)(c) requires the lowest-floor elevation to be certified by a California-licensed land surveyor or civil engineer and submitted to the local administrator. 050(A)(3)(f) so they aren't later finished as living space without full compliance.

Violations & Fines

Chapter 15.104 falls within Title 15, so failing to meet the elevation and certification requirements is enforced under § 15.04.060 as a misdemeanor for each day the violation continues, with civil penalties of $250 to $25,000 per day; unauthorized conversion of below-BFE enclosed space also breaches the recorded non-conversion agreement tied to the permit.

Frequently Asked Questions

How much freeboard does Sacramento require above base flood elevation?
In Zones A, AH, and AE, § 15.104.050(A)(3)(a) requires the lowest floor of new construction and substantial improvements to be elevated at least one foot above the base flood elevation, with that data sealed by a California-licensed civil engineer in Zone A.
Is the elevation rule different near Magpie Creek?
Yes. The Magpie Creek floodplain has a dual standard: the lowest floor must be at least one foot above the highest adjacent 100-year flood hydraulic grade line and at least 18 inches above the controlling overland release point in the public right-of-way.
Do HVAC and electrical equipment need to be elevated too?
Yes. Section 15.104.050(A)(3)(j) requires electrical, heating, ventilation, plumbing, and air conditioning equipment to be elevated or dry-floodproofed to one foot above the base flood elevation, matching the structural freeboard standard.
Who signs off on the finished elevation of my Sacramento home?
Section 15.104.050(A)(3)(c) requires a California-licensed land surveyor or civil engineer to certify that the completed structure's lowest floor was properly elevated, with that certification submitted to the local administrator.

Sources & Official References

Other rules in Sacramento

All Sacramento rules

California rules heatmap·Compare Sacramento to another location·View the California environmental rules overview

Get notified when Flood Elevation Requirements in Sacramento, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Sacramento County handle flood elevation requirements.

Folsom, CA
Some Restrictions
Elk Grove, CA
Some Restrictions
Rancho Cordova, CA
Some Restrictions