Key Facts

Standard freeboard
2 ft above base flood elevation
Slab-on-grade pad
1.5 ft above BFE minimum
Critical facilities
3 ft above BFE or 500-yr level
Unmapped areas
2 ft above admin.-set BFE
Certification required
registered civil engineer or surveyor

Summary

New subdivisions and development in Elk Grove's special flood hazard areas must elevate the lowest finished floor at least two feet above the base flood elevation under EGMC Section 16.50.060(C)(1)(d). Slab-on-grade pads need at least 1.5 feet of freeboard, and critical facilities like hospitals and nursing homes need three feet or the 500-year flood elevation, whichever is higher.

In special flood hazard areas, elevate the lowest finished floor at least two (2'0") feet above the base flood elevation. Building pads for slab-on-grade construction shall be at least one and one-half (1' 6") feet above the base flood elevation and the lowest finished floor shall be at least two (2' 0") feet above the base flood elevation. For critical infrastructures, such as nursing homes and hospitals, the lowest finished floor shall be at least three (3' 0") feet above the base flood elevation or the elevation corresponding to the five hundred (500) year floodplain, whichever is greater.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4937385; v2 updated 2026-05-13; through 05-13-2026).

Full Breakdown

EGMC Section 16.50.060(C) sets the elevation standards that apply once a project sits inside a FEMA-mapped special flood hazard area and needs a floodplain development permit under Section 16.50.050. For all new subdivisions, manufactured home parks, and other new development, subsection (C)(1)(d) requires the lowest finished floor to sit at least two feet above the base flood elevation (BFE), the surface elevation of the flood having a one-percent annual chance of occurrence. Building pads for slab-on-grade construction must reach at least one and one-half feet above the BFE before that two-foot finished-floor freeboard is even measured. Critical infrastructure, the code names nursing homes and hospitals as examples, has to clear three feet above the BFE or the elevation of the 500-year floodplain, whichever produces the higher elevation.

In areas without FEMA-mapped BFEs, subsection (C)(1)(e) still requires two feet of freeboard above a BFE the Floodplain Administrator establishes under Section 16.50.030(B)(4), and slab-on-grade pads in those unmapped areas must also clear two feet above that administratively determined BFE. Where a developer proposes to raise a site above the BFE using fill, subsection (C)(1)(f) requires filing a conditional letter of map revision based on fill (CLOMR-F) with FEMA before the City treats the site as elevated. Elevation of new floor area on remodels to existing structures is handled separately under Section 16.50.060(A)(3)(a): two feet of freeboard in Zone AE or AH, the FIRM depth number or two feet in Zone AO, and BFE compliance in unmapped A Zones. All new floor elevations must be certified by a registered civil engineer or licensed land surveyor and the certification filed with the Floodplain Administrator.

Violations & Fines

Building below the required freeboard in a mapped special flood hazard area violates EGMC Chapter 16.50 and constitutes a misdemeanor under Section 16.50.040(C). The Floodplain Administrator can withhold or condition the floodplain development permit until elevation certificates from a registered civil engineer or licensed land surveyor confirm the required height, and the City may take other lawful action to remedy noncompliant construction.

Frequently Asked Questions

How high above the flood line must a new Elk Grove home be built?
At least two feet above the base flood elevation for the lowest finished floor, per Section 16.50.060(C)(1)(d). The building pad itself must reach at least one and one-half feet above the BFE for slab-on-grade construction, and a licensed engineer or surveyor must certify the finished elevation to the Floodplain Administrator.
Does Elk Grove require extra flood freeboard for hospitals or nursing homes?
Yes. Critical infrastructure such as nursing homes and hospitals must reach at least three feet above the base flood elevation, or the elevation of the 500-year floodplain if that is higher, under Section 16.50.060(C)(1)(d).
What if my Elk Grove property has no FEMA-mapped base flood elevation?
The Floodplain Administrator establishes a BFE under Section 16.50.030(B)(4), and Section 16.50.060(C)(1)(e) still requires the lowest finished floor and any slab-on-grade pad to sit at least two feet above that administratively determined elevation.

Sources & Official References

Other rules in Elk Grove

All Elk Grove rules

California rules heatmap·Compare Elk Grove to another location·View the California environmental rules overview

Get notified when Flood Elevation Requirements in Elk Grove, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Sacramento County handle flood elevation requirements.

Sacramento, CA
Some Restrictions
Folsom, CA
Some Restrictions
Rancho Cordova, CA
Some Restrictions