Waukegan, IL Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard
2.5 feet above flood protection elevation
Wall openings
No lower than elevation plus 2.5 ft
Basement construction
Watertight masonry, engineer-sealed design
Building site grading
Slopes away from walls, 5 feet min
Datum
Mean sea level, New York City

Summary

Waukegan sets its regulatory flood protection elevation 2.5 feet above the mapped high-water profile, and Sec. 6-131 carries that same 2.5-foot freeboard into construction rules, requiring every doorsill, windowsill, or wall opening to sit no lower than that elevation plus 2.5 feet.

(a)Profile drawings and schedules. Profile drawings and schedules provided in United States Geological Survey Hydrological Investigations Atlas, Series HA, dated 1964 through 1971, accompanying and identified as part of this article, are incorporated herein for the purpose of establishing regulatory flood protection elevations on or along the streams, channels and basins established in section 6-93 of this article. The regulatory flood protection elevation shall be 2.5 feet above the attached water surface profiles provided in United States Geological Survey Hydrological Investigations Atlas, Series HA, where a flood of record has not been determined. ... A doorsill, windowsill or the base of any other opening in the outer walls of a main building or structure, including drain conduits, shall be constructed at an elevation not lower than the established regulatory flood protection elevation plus 2.5 feet, unless surrounded by a watertight areaway the top of which is not lower than such minimum elevation.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 113).

Full Breakdown

Sec. 6-95(a) ties Waukegan's regulatory flood protection elevation to the profile drawings and schedules in the USGS Hydrological Investigations Atlas referenced in Sec. 5 feet above the attached water-surface profile. Subsection (b) applies the elevation nearest to a given building, lot, or parcel, measured at right angles to the flow of the adjoining stream or channel, or from the nearest detention pond or basin, whichever produces the higher elevation, and subsection (c) datums those elevations to mean sea level at New York City unless the profile notes a different reference point.

That base elevation then drives the article's construction standards: Sec. 5 feet of freeboard, unless it is protected by a watertight areaway built to that same minimum height. Sec. 5-foot line to be built of watertight masonry engineered by a state-registered architect or engineer to resist hydrostatic pressure, and Sec. 6-133 requires the building site itself to be graded to that height and slope away from the walls for at least five feet.

Violations & Fines

Sec. 6-116 withholds zoning, building, and subdivision permits until a project meets the elevation standards in Sec. 6-95, 6-131, 6-132, and 6-133, so a wall opening, basement, or building pad built below the required flood protection elevation plus 2.5 feet of freeboard cannot receive city approval, and Sec. 6-132's watertight-construction design must carry a licensed architect's or engineer's seal before it is accepted.

Frequently Asked Questions

How much freeboard does Waukegan require above the base flood elevation?
2.5 feet. Sec. 6-95(a) sets the regulatory flood protection elevation itself at 2.5 feet above the mapped water-surface profile, and Sec. 6-131 adds another 2.5 feet on top of that for doorsills, windowsills, and other wall openings.
Do basement walls need special construction in a Waukegan flood area?
Yes. Sec. 6-132 requires outer walls, basement floors, and areaways below the elevation-plus-2.5-foot line to be watertight masonry designed to resist hydrostatic pressure, with the design sealed by a state-registered architect or engineer.
Can I use a watertight areaway instead of raising a doorsill?
Yes. Sec. 6-131 allows a watertight areaway around a low opening as long as the top of the areaway itself is not lower than the required flood protection elevation plus 2.5 feet.

Sources & Official References

Other rules in Waukegan

All Waukegan rules

Compare Waukegan to another location·View the Illinois environmental rules overview

Get notified when Flood Elevation Requirements in Waukegan, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.