Gretna, LA Environmental Rules: Stormwater Management (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Runoff maintenance duty
property owner (§ 10-15(a)(3))
Retaining wall min. thickness
6 inches, reinforced concrete/masonry
Engineer-stamped wall trigger
over 12 inches above grade
Drainage plan required
lots 200+ feet deep
Occupancy hold
no C.O. until servitude/facilities installed

Summary

Gretna Code of Ordinances § 10-15 makes the property owner responsible for maintaining approved drainage arrangements, whether a retaining wall, sub-surface drainage, or a swale, and requires new construction that would drain onto a higher-elevation neighboring lot to dedicate a recorded drainage servitude and install drainage facilities before occupancy.

(a)Generally. To establish appropriate grade or elevation for lots, structures, and facilities, the following general standards shall apply: ( ... 3)Runoff. ... The approved arrangements for handling direct run off (whether by retainer wall, approved sub-surface drainage, swale, or other approved alternative) shall be properly maintained by the property owner. ... (e)Drainage servitude and facilities.(1)In the case where the rear of the lot on which the new construction is proposed adjoins a lot on which a residence or building already exists, and which lot drains to the rear and the required elevation on the lot where the new construction is proposed is higher than the existing elevation of the lot on which the residence or building exists, then:a.A drainage servitude on the lot containing the new construction is dedicated and properly recorded to drain the lot on which the residence or building already exists; andb.Drainage facilities are properly installed on the lot containing the new construction.

Full Breakdown

Section 10-15, "Lot grade rules and regulations," sets Gretna's local drainage standard on top of the state building code. Subsection (a)(3), Runoff, states that "the approved arrangements for handling direct run off (whether by retainer wall, approved sub-surface drainage, swale, or other approved alternative) shall be properly maintained by the property owner," putting ongoing maintenance squarely on the homeowner rather than the city. Where one lot sits higher than its neighbor, subsection (b) requires an approved arrangement to keep water from flowing directly onto the lower lot, and if the code official finds the elevation difference too great for a swale, a reinforced concrete or masonry retaining wall at least six inches thick is required on the rear and side property lines, extending two to six inches above the highest adjacent grade.

Retaining walls over 12 inches high, or that extend below the lower adjacent grade by less than their own height, must be designed and stamped by a design professional under subsection (b)(2). Subsection (e), Drainage servitude and facilities, addresses the case where new construction would sit higher than an existing rear-lot structure that drains to the rear: the builder must dedicate and record a drainage servitude on the new-construction lot and properly install drainage facilities there, and no certificate of occupancy or utility notification can issue until that servitude and those facilities are in place.

Lots 200 feet deep or more also require a design-professional-certified drainage plan filed with the building permit application under subsection (d), fully implemented before the final building inspection is scheduled.

Violations & Fines

Failing to maintain approved drainage under § 10-15, or building without the required drainage servitude, retaining wall, or drainage plan, is enforced by the building official and blocks the certificate of occupancy under subsection (e)(2) until the servitude and facilities are in place. A separate violation is punishable under Gretna's general penalty, § 1-8(d), by a fine of up to $500.00, with continuing violations treated as a separate offense each day.

Frequently Asked Questions

Who is responsible for maintaining drainage on a Gretna lot?
The property owner. Section 10-15(a)(3) requires the approved drainage arrangement, whether a retaining wall, sub-surface drainage, or swale, to be properly maintained by whoever owns the lot.
Does Gretna require a drainage servitude for new construction?
Yes, when the new construction sits higher than an existing rear-lot structure that drains to the rear. Section 10-15(e) requires a recorded drainage servitude and installed drainage facilities before the new residence can be occupied.
When does Gretna require an engineer-stamped retaining wall?
Under § 10-15(b)(2), a retaining wall more than 12 inches above the lowest adjacent grade, or one that extends below the lower grade by less than its own height, must be designed and stamped by a design professional.
What triggers a certified drainage plan in Gretna?
A residential lot 200 feet deep or more requires a design-professional-certified lot drainage plan filed with the building permit application under § 10-15(d), and it must be fully implemented before the final inspection.

Sources & Official References

Other rules in Gretna

All Gretna rules

Compare Gretna to another location·View the Louisiana environmental rules overview

Get notified when Stormwater Management in Gretna, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.