Rothschild, WI Fire Regulations: Smoke Detectors (2026)
Key Facts
- State code adopted
- SPS 328, Wis. Adm. Code, via § 306-21
- Testing frequency
- Every six months minimum
- Record retention
- 7 years on site
- Noncompliance remedy
- Inspector-ordered system replacement
- General penalty
- $10 to $100 first offense (§ 1-2)
Summary
Rothschild adopts Wisconsin's SPS 328 smoke and carbon monoxide detector code by reference and layers its own testing rule on top: every smoke detector, battery or hardwired, must be tested at least once every six months with records kept on site for seven years under § 306-44.
The Village hereby adopts the following chapters from the Wisconsin Administrative Code, Department of Safety and Professional Services. These regulations are adopted by reference and incorporated into the Village Fire Prevention Code with the same force and effect as if fully set forth herein. ... SPS 328 Smoke Detectors and Carbon Monoxide Detectors ... Smoke detection systems. Whether battery-operated or electrically interconnected, all smoke detectors shall be tested at least once every six months. Written records shall be maintained showing test results, dates, duration of tests, locations and who performed the tests. Records shall be kept on site and available for inspection for a period of no less than seven years.
Full Breakdown
Article V of the Fire Prevention chapter, § 306-21, adopts a list of Wisconsin Administrative Code chapters into the Village Fire Prevention Code with the same force and effect as if fully set forth herein, including SPS 328, Smoke Detectors and Carbon Monoxide Detectors, alongside the state's Uniform Dwelling Code (SPS 320-325) and Commercial Building Code (SPS 361-366). Any future state amendment to SPS 328 becomes Village law automatically without a local ordinance change.
Section 306-44A adds Rothschild's own maintenance standard on top of the adopted state code: whether battery-operated or electrically interconnected, all smoke detectors must be tested at least once every six months, with written records of the test date, duration, location and tester kept on site and available to the Fire Inspector for at least seven years. If those records go missing or become more than a year out of date, and the detectors themselves turn out to be missing or inoperable, the Fire Inspector can order the owner to install or replace the whole system with new, electrically interconnected detectors tied into a fire alarm control panel, at the owner's expense. The same six-month testing and seven-year recordkeeping standard applies in parallel to manual pull-station fire alarms under § 306-44B.
Violations & Fines
Failing to test detectors on the six-month schedule or keep the required seven-year records exposes an owner to a Fire Inspector order to install a new, interconnected detector and alarm-panel system at their own cost. Beyond that remedy, any violation of Chapter 306 falls under § 306-18, which routes to the Village's general penalty, § 1-2: $10 to $100 for a first offense, $50 to $500 for a repeat violation within a year.
Frequently Asked Questions
How often must smoke detectors be tested in Rothschild?
What state code governs smoke detectors here?
What happens if my detectors are missing or records are out of date?
Sources & Official References
Other rules in Rothschild
Compare Rothschild to another location·View the Wisconsin fire regulations overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Smoke Detectors in Nearby Cities
How other cities in Marathon County handle smoke detectors.