Skip to main content
CityRuleLookup

Southampton, NY Hurricane Preparedness: Flood Elevation (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Applies to
VE Zones and Coastal A Zones
Minimum elevation
2 feet above BFE, lowest structural member
Foundation support
Pilings, columns or shear walls required
Pile penetration
5 to 10 ft below mean sea level
Penalty
Up to $1,000 fine or 15 days, per day

Summary

For homes in the Town of Southampton's coastal high-hazard VE Zones and Coastal A Zones, hit hardest by hurricane storm surge, Town Code § 169-17 requires the lowest structural member to be elevated on pilings, columns or shear walls at least two feet above base flood elevation.

§ 169-17. Residential structures (coastal high-hazard areas and Coastal A Zones). ... The following standards, in addition to the standards in § 169-14A, coastal high-hazard areas and Coastal A Zones, § 169-14B, Subdivision and development proposals, and § 169-15, Standards for all structures, apply to new and substantially improved residential structures located in areas of special flood hazard shown as VE and Coastal A Zones: A. Elevation. New construction and substantial improvements shall be elevated on pilings, columns or shear walls such that the bottom of the lowest horizontal structural member supporting the lowest elevated floor (excluding columns, piles, diagonal bracing attached to the piles or columns, grade beams, pile caps and other members designed to either withstand storm action or break away without imparting damaging loads to the structure) is elevated to or above two feet above base flood elevation so as not to impede the flow of water, as identified in the Flood Insurance Rate Map (FIRM) for the Town of Southampton as established in § 169-6.

Full Breakdown

Beyond the general AE Zone elevation standard, the Town Board wrote a separate, stricter set of construction rules in § 169-17 for residential structures in coastal high-hazard areas and Coastal A Zones, the ocean- and bay-facing hamlet shoreline exposed to hurricane wave action and storm surge. New construction and substantial improvements must be elevated on pilings, columns or shear walls so the bottom of the lowest horizontal structural member sits at or above two feet above the base flood elevation shown on the Town's FEMA Flood Insurance Rate Map adopted in § 169-6, so floodwater and wave runup can pass beneath the building without impeding flow.

Section 169-17B requires the structural design to account for wind and water loads acting simultaneously during the base flood, including wave inertia, drag and impact forces from waterborne storm debris, using wind loading values from the Building Code. Foundation standards in § 169-17C bar spread footings and fill material for structural support, and pile foundation design under § 169-17D sets a minimum pile-spacing-to-diameter ratio of eight to one, a maximum twelve-foot on-center spacing for load-bearing wood piles, and minimum pile penetration to five feet below mean sea level where the base flood elevation is +10 feet or less, or ten feet below mean sea level where it exceeds +10 feet.

The space below the lowest floor in VE Zones must be free of obstruction or built with breakaway walls, lattice or insect screening designed to collapse under storm loads, and may be used only for parking, access or storage, never human habitation, per § 169-15B(4).

Violations & Fines

Constructing, locating, extending, converting or altering a structure in the coastal high-hazard area without complying with Chapter 169, including the § 169-17 elevation and foundation standards, is a violation under § 169-8: conviction carries a fine of up to $1,000 or up to 15 days' imprisonment, or both, with each day of noncompliance a separate offense. A structure without the required elevation certificate is presumed noncompliant, and the Town notifies FEMA of structures found in violation that lack an approved § 169-21 variance.

Frequently Asked Questions

How are homes in Southampton's storm-surge zones required to be elevated?
Under § 169-17A of the Town Code, new construction and substantial improvements in VE Zones and Coastal A Zones must be elevated on pilings, columns or shear walls so the lowest horizontal structural member sits at or above two feet above the base flood elevation, letting storm surge and waves pass underneath.
Can the space under an elevated coastal home be finished living space?
No. Section 169-15B(4) limits the enclosed area below the lowest floor in VE Zones to parking, building access or storage, and expressly prohibits its use for human habitation.
How deep must pilings be driven in Southampton's coastal high-hazard areas?
Section 169-17D(2) requires piles to penetrate to at least five feet below mean sea level where the base flood elevation is +10 feet or less, or at least ten feet below mean sea level where the base flood elevation is greater than +10 feet.

Sources & Official References

Other rules in Southampton

All Southampton rules

New York rules heatmap·Compare Southampton to another location·View the New York hurricane preparedness overview

Get notified when Flood Elevation in Southampton, NY changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation in Nearby Cities

How other cities in Suffolk County handle flood elevation.

Huntington, NY
Some Restrictions