Southampton Village, NY Hurricane Preparedness: Flood Elevation (2026)

Significant Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified October 2026

Key Facts

Zones covered
V1-V30, VE, V and Coastal A
Required elevation
Bottom of lowest horizontal member two feet above base flood elevation
Foundation
Pilings, columns or shear walls; no spread footings or fill
Siting
Landward of the reach of high tide
Space below elevated floor
Parking, building access or storage only
Wood pile spacing
No more than 12 feet on center under load bearing members

Summary

In the Village of Southampton's V, VE and Coastal A flood zones, new and substantially improved homes must stand on pilings, columns or shear walls with the bottom of the lowest horizontal structural member at least two feet above base flood elevation. Spread footings and fill cannot carry the structure, and the design must resist wind and water loads acting together.

The following standards, in addition to the standards in § 62-15A, Coastal high hazard areas and Coastal A Zones, and § 62-15B, Subdivision and development proposals, and § 62-16, Standards for all structures, apply to new and substantially improved residential structures located in areas of special flood hazard shown as Zones V1-V30, VE, V, or Coastal A on the community's Flood Insurance Rate Map designated in § 62-6. A. Elevation. New construction and substantial improvements shall be elevated on pilings, columns or shear walls such that the bottom of the lowest horizontal structural member sup- porting the lowest elevated floor (excluding columns, piles, diagonal bracing attached to the piles or columns, grade beams, pile caps and other members designed to either withstand storm action or break away without imparting damaging loads to the structure) is elevated to or above two feet above base flood elevation so as not to impede the flow of water. ... (2) Spread footings and fill material shall not be used for structural support of a new building or substantial improvement of an existing structure.

Full Breakdown

Section 62-18 governs residential structures in the Village's coastal high hazard areas, the zones mapped as V1-V30, VE, V or Coastal A on the FEMA Flood Insurance Rate Map. Its standards stack on top of § 62-15(A), § 62-15(B) and § 62-16. Under § 62-15(A), all new construction in those zones must be located landward of the reach of high tide, the use of fill for structural support is prohibited, and man-made alteration of sand dunes that would increase potential flood damage is prohibited.

Elevation is measured to the bottom of the lowest horizontal structural member supporting the lowest elevated floor, which must be at or above two feet above base flood elevation so as not to impede the flow of water. Columns, piles, diagonal bracing, grade beams, pile caps and other members designed to withstand storm action or break away are excluded from that measurement.

The structure has to carry the storm. Section 62-18(B) requires the design to consider wind and water loads acting simultaneously during the base flood, including wave inertial and drag forces, current drag forces and impact forces from waterborne storm debris, with dynamic uplift loads considered where bulkheads, walls or other obstructions could cause wave runup beyond the base flood elevation. The design ratio of pile spacing to pile diameter cannot be less than 8:1 for individual piles, wood piles can be no more than 12 feet on center under load bearing sills, beams or girders, and minimum penetration is to five feet below mean sea level datum when the base flood elevation is +10 msl or less, or at least 10 feet below msl when it is greater. Round timber piles need a tip diameter of 8 inches, and toe nailing as a principal method of connection is not permitted.

Space below the elevated floor is restricted. Under § 62-16(B)(4) it must be free from obstruction or enclosed only with non-supporting breakaway walls, open wood lattice-work or insect screening, and it can be used only for parking vehicles, building access or storage. Human habitation there is expressly prohibited. Breakaway wall designs with strengths over 20 pounds per square foot need certification from a licensed professional engineer or architect with the permit application (§ 62-13(I)).

Violations & Fines

Non-compliant coastal construction is punishable under § 62-9 by a fine of no more than $250 or imprisonment for not more than 15 days, or both, with each day of noncompliance a separate offense. The local administrator issues a stop-work order for non-compliant development, and in V zones the certificate of elevation for the bottom of the lowest structural member must be submitted when the lowest floor is placed. Work done before approval of that certification proceeds at the permit holder's risk (§ 62-14).

Frequently Asked Questions

How high above the flood level must a coastal house be in the Village of Southampton?
In V1-V30, VE, V and Coastal A zones, § 62-18(A) requires the bottom of the lowest horizontal structural member supporting the lowest elevated floor to be at or above two feet above base flood elevation. The house must be raised on pilings, columns or shear walls so it does not impede the flow of water.
Can I enclose the space under an elevated house in a V zone?
Only with non-supporting breakaway walls, open wood lattice-work or insect screening, or leave it free from obstruction. Section 62-16(B)(4) limits that space to parking vehicles, building access or storage, and expressly prohibits human habitation. Stairs, stairwells and elevator shafts there are subject to the same design requirements as breakaway walls.
Can fill be used to raise a lot or support a house in a V zone?
No. Section 62-15(A)(2) prohibits the use of fill for structural support of buildings in V and Coastal A zones, and § 62-18(C)(2) adds that spread footings and fill material cannot be used for structural support of a new building or a substantial improvement. Man-made alteration of sand dunes that would increase flood damage is also prohibited.
What elevation certificate is required once the floor is placed?
Under § 62-14(D)(2), the permit holder submits a certificate of elevation of the bottom of the lowest structural member of the lowest floor, excluding pilings and columns, in relation to mean sea level. It is prepared by or under the direct supervision of a licensed land surveyor or professional engineer and certified by that person.

Sources & Official References

Other rules in Southampton Village

All Southampton Village rules

New York rules heatmap·Compare Southampton Village to another location·View the New York hurricane preparedness overview

Get notified when Flood Elevation in Southampton Village, NY changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation in Nearby Cities

How other cities in Suffolk County handle flood elevation.

Huntington, NY
Some Restrictions