Roanoke, VA Outdoor Lighting: Dark Sky Rules (2026)
Key Facts
- Pole height, residential, MX and IN districts
- 18 feet maximum, at least 10 feet from any lot line
- Pole height, all other districts
- 35 feet maximum
- House shield trigger
- Pole within 30 feet of a residentially zoned lot
- Building-mounted lights
- Must be mounted below the roof line
- Lighting plan required
- Light support structures over 8 feet tall
- Motion-sensor security exemption
- Illumination of 15 minutes or less
- Enforcement
- Zoning Administrator; misdemeanor and injunction
Summary
Roanoke's zoning ordinance requires all outdoor lighting to be fully shielded, or aimed and shielded, so it throws no glare onto abutting lots or streets. Pole-mounted fixtures stop at 18 feet in residential, MX and IN districts and 35 feet in every other district, and feeds to lighting standards must run underground.
All outdoor lighting shall be fully shielded or located, aimed, and shielded so as not to present glare on abutting lots or streets and to minimize spill light trespassing upward or across lot lines. ... No outdoor lighting shall be permitted which shines directly into abutting residential dwelling units, buildings on adjacent lots, or abutting streets, or for which the point source of illumination (arc tube) is visible at the property line. ... In all residential districts, the MX, Mixed Use District, and the IN, Institutional District, pole-mounted lighting shall be located no closer than ten (10) feet to any lot line and shall not exceed eighteen (18) feet in height ... In all zoning districts, other than those set forth in subsection (A) above, pole-mounted lighting shall not exceed thirty-five (35) feet in height, measured from the lowest light-emitting part of the fixture to the adjacent grade. Pole-mounted lighting within thirty (30) feet of an abutting lot line of a residentially zoned property shall be equipped with a house shield which side shields the light fixture on the side of the residentially zoned lot.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 94 Update 1).
Full Breakdown
Section 36.2-625 is the working standard for Roanoke's outdoor lighting division. Subsection (a) sets four general rules. Every fixture must be fully shielded, or located, aimed and shielded, so it does not glare onto abutting lots or streets and keeps spill light from climbing upward or crossing a lot line. No fixture can shine directly into a neighbor's dwelling unit, a building on an adjacent lot or an abutting street, and the arc tube cannot be visible at the property line. Electrical feeds to lighting standards go underground, not overhead. Building-mounted uplighting is allowed only where an overhanging architectural element can functionally contain or limit the light beyond the roof.
Subsection (b) sets mounting heights. In all residential districts, the MX Mixed Use District and the IN Institutional District, a pole must sit at least 10 feet from any lot line and cannot exceed 18 feet, measured from the lowest light-emitting part of the fixture to the adjacent grade. In every other district the ceiling is 35 feet, and any pole within 30 feet of an abutting residentially zoned lot needs a house shield on the side facing that lot. Any building-mounted light must be mounted below the roof line.
The standards apply when lighting is installed or replaced, including a change in fixture type, height or location, in connection with a basic or comprehensive development plan, a new light support structure over 8 feet tall, new flood or spot lights on existing structures in residential districts, or new fixtures on existing structures in nonresidential districts (Section 36.2-621). Routine maintenance such as changing lamps, ballasts or lenses is not replacement. Section 36.2-620 states the purpose: controlling light trespass and glare in line with the City's Comprehensive Plan policy of reducing light pollution, particularly in residential neighborhoods.
Section 36.2-622 exempts specific lighting, including illuminated signs governed by Section 36.2-666, landscape lighting two feet or less in height, motion-sensor security lighting that runs 15 minutes or less, temporary holiday and construction lighting, submerged pool lighting and FAA-required lighting. Section 36.2-624 requires a lighting plan with the application, showing fixture locations, mounting heights, manufacturer cut sheets and building elevations.
Violations & Fines
The Zoning Administrator enforces the lighting rules under Section 36.2-571. A complaint triggers an investigation, and a confirmed violation draws a written notice to the owner or responsible person that names the violation and orders the corrective action. Violating or permitting a violation of the zoning chapter is a misdemeanor punishable as provided in Section 15.2-2286.A.5 of the Code of Virginia, and the City can also seek an injunction to restrain, correct or abate the lighting, alone or alongside a criminal case. These remedies are cumulative with any other remedy provided by law. Appeals of a zoning determination go to the board of zoning appeals under Section 36.2-562.
Frequently Asked Questions
How tall can a light pole be in a Roanoke residential neighborhood?
Can my outdoor light shine onto my neighbor's house in Roanoke?
Do I need a lighting plan to install a new pole light in Roanoke?
Which lights are exempt from Roanoke's lighting standards?
Can I run overhead wires to a new light standard in Roanoke?
Sources & Official References
Other rules in Roanoke
Compare Roanoke to another location·View the Virginia outdoor lighting overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.